Stovax Marlborough 8560, Stockton 8573, P8564 Installation Instructions, Technical Specification

Page 10

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATION

 

 

Model

Gas

Gas

Working

NOX

 

Aeration

Injector

Gas Rate

Input kW (Gross)

Country

 

 

CAT.

 

Type

Pressure

Class

 

 

 

m3⁄h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

Low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Small:

8560 - Marlborough

I2H

Naural Gas G20

20 mbar

5

 

ø7 mm

260

0.433

4.55

2.5

GB,IE

 

 

8573 - Stockton

 

 

 

 

 

 

 

 

 

 

 

Gross

Gross

 

 

 

P8560 - Marlborough

I3+

LPG Propane G31

37 mbar

5

 

ø13 mm

120

0.173

4.60

2.5

GB,IE

 

 

P8573 - Stockton

LPG Butane G30

29 mbar

 

0.131

 

 

 

 

 

 

 

Gross

Gross

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium:

8564- Marlborough

I2H

Naural Gas G20

20 mbar

5

 

ø11 mm

375

0.639

6.60

3.25

GB,IE

 

 

8574 - Stockton

 

 

 

 

 

 

 

 

 

 

 

Gross

Gross

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P8564 - Marlborough

I3+

LPG Propane G31

37 mbar

5

 

ø15.5 x 2

170

0.237

6.30

3.25

GB,IE

 

 

P8574 - Stockton

LPG Butane G30

29 mbar

 

0.18

 

 

 

 

 

 

 

Gross

Gross

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Large:

8568- Marlborough

I2H

Naural Gas G20

20 mbar

5

 

ø13 mm

560

0.848

8.90

4.0

GB,IE

 

 

 

 

 

 

 

 

 

 

 

Gross

Gross

 

 

 

P8568- Marlborough

I3+

LPG Propane G31

37 mbar

5

 

ø15.5 x 2

240

0.35

9.30

4.0

GB,IE

 

 

LPG Butane G30

29 mbar

 

ø13.0 x 1

0.266

 

 

 

 

 

 

 

Gross

Gross

 

 

 

 

 

 

Efficiency

Class II

 

 

 

 

 

 

 

 

 

 

 

Flue Outlet Size 127 mm (5”) ø

 

 

 

 

 

 

 

 

 

Gas Inlet Connection Size 8 mm ø

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum flue specification T260/N2/O/D/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum flue temperature 180°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

E

 

 

Packing Checklist

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Qty

Description

 

 

 

 

 

 

 

 

 

 

 

1

Stove

 

 

 

 

 

 

 

 

 

 

 

1

Flue Blanking plate

 

 

 

 

 

 

B

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Flue In fill plate

1Coal set*

1

Flame Baffle*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Front Coal*

Marlborough

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Fixing kit containing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

B

 

 

 

C

 

 

 

D

 

 

 

E

 

 

 

F

1

Instruction Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ins

 

mm

 

ins

 

mm

 

ins

 

 

mm

 

ins

 

mm

 

ins

 

mm

 

ins

 

mm

2

Wood screws

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Small

161/8

 

410

 

21

 

533

 

11

 

280

137/8

 

352

43/8

 

111

31/8

 

80

2

Rawlplugs

 

 

Medium

231/4

 

590

 

23

 

583

 

13

 

330

153/4

 

401

 

4

 

 

101

31/8

 

80

1

Box spanner

 

 

Large

283/4

 

675

 

243/4

 

628

 

133/8

 

340

 

171/2

 

446

 

4

 

 

101

 

31/8

 

80

*Packed in appliance

Stockton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

F

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

B

 

 

 

 

C

 

 

 

 

 

 

D

 

 

 

 

 

 

E

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ins

 

mm

 

 

ins

 

mm

 

ins

 

mm

 

ins

 

mm

 

 

ins

 

mm

 

 

ins

 

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Small

165/8

 

422

205/8

 

525

111/2

 

290

135/8

 

346

 

43/8

 

110

 

 

2

 

50

 

 

 

 

Medium

223/4

 

579

 

243/16

 

618

 

135/8

 

345

 

 

163/4

 

425

 

 

4

 

102

 

 

25/8

 

66

 

 

 

 

 

 

 

 

 

 

 

 

10

Image 10
Contents Marlborough & Stockton Coal Effect Stove Range Contents Flue Check Pass Fail Appliance Commissioning ChecklistGAS Check General User InstructionsLighting the Appliance Turning the Stove OFF Cleaning the FireAdvice on Handling and disposal of fire ceramics Upgrading Your StoveSmall Marlborough and Stockton Medium Marlborough and Stockton Large Marlborough Flame Failure Device Installation DetailsGazco Flue Sure System RunningTechnical Specification Installation InstructionsIns Flue and Chimney Requirements Installation of the GAS SupplySite Requirements Appliance LocationSafety Precautions InstallationControl Upgrade Installation of the StoveClosure Plate Installation AR0361 AR0369 AR0374 Commissioning CommissioningServicing Instructions Servicing / Fault Finding ChartsServicing Requirements Ignition Functional Check Fault Finding ChartsFlame Failure Functional Check Replacing Parts Burner Unit RemovalIgnition Lead and Piezo Pilot UnitPiezo Magnetic Safety Valve GAS ValvePrimary Aeration Plate Main InjectorChanging Between GAS Types Short Spares List LPGService Records Page Page Member of the Stovax Group