INSTALLATION INSTRUCTIONS

INSTALLATION

Medium Marlborough and Stockton 8

6.8Place the flame baffle onto the shelf at the rear of the tray and push up against the rear ledge, see diagram 12.

12

AR0365

6.9Locate the front coal moulding in front of the flame baffle ensuring that the end legs sit flat against the burner skin, see diagram 13.

13

AR0366

6.10Place three large coals on the front coal so that they lean against the flame baffle, and the four large coals on the flame baffle so that they sit on the fingers, see diagram 14.

14

6.11Place two small coals at each end of the front coal so that they lean against the flame baffle, and a further two large coals on the flame baffle, one at each end, see diagram 15.

15

AR0368

6.12Place five small coals along the rear of the flame baffle, resting against the rear ledge, see diagram 16.

16

AR0369

6.13Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four brass nuts and the tool supplied, do not over tighten the nuts, see diagram 17. Keep the tool with these instructions for future use.

17

AR0367

AR0390

NEVER OPERATE THE STOVE WHEN THE DOOR IS REMOVED OR WHEN THE GLASS IS BROKEN.

15

Image 15
Contents Marlborough & Stockton Coal Effect Stove Range Contents Appliance Commissioning Checklist Flue Check Pass FailGAS Check User Instructions GeneralLighting the Appliance Upgrading Your Stove Cleaning the FireAdvice on Handling and disposal of fire ceramics Turning the Stove OFFSmall Marlborough and Stockton Medium Marlborough and Stockton Large Marlborough Running Installation DetailsGazco Flue Sure System Flame Failure DeviceInstallation Instructions Technical SpecificationIns Appliance Location Installation of the GAS SupplySite Requirements Flue and Chimney RequirementsInstallation of the Stove InstallationControl Upgrade Safety PrecautionsClosure Plate Installation AR0361 AR0369 AR0374 Commissioning CommissioningServicing / Fault Finding Charts Servicing InstructionsServicing Requirements Fault Finding Charts Ignition Functional CheckFlame Failure Functional Check Burner Unit Removal Replacing PartsPilot Unit Ignition Lead and PiezoPiezo GAS Valve Magnetic Safety ValveMain Injector Primary Aeration PlateChanging Between GAS Types LPG Short Spares ListService Records Page Page Member of the Stovax Group