Stovax P8574, Marlborough 8560, Stockton 8573 Closure Plate Installation, Fuel BED Arrangement

Page 13

INSTALLATION INSTRUCTIONS

INSTALLATION

There is a cutout in the RH rear leg to enable a direct straight connection to be made to the rear of the stove. See diagram 3. A gas soundness check must be completed up to the gas inlet connection.

4.5Check the pull of the flue system by applying a lighted smoke pellet to the flue system opening. If there is a definite flow into the chimney, proceed with the installation. If not, warm the chimney for a few minutes.

IF THERE IS STILL NO DEFINITE FLOW, THE FLUE MAY REQUIRE ATTENTION - SEEK EXPERT ADVICE

4.6The flue system may now be connected to the stove. Ensure that all joints are sealed with a suitable fire resistant sealant. It is also recommended that a physical retention method be used at the flue spigot joint, self-tapping screws are recommended..

4.7Connect a suitable pressure gauge to the test point located on the inlet fitting and turn on the gas supply. Light the appliance and check all gas joints for gas soundness. Turn the appliance to a maximum and check that the supply pressure is as stated on the databadge. Turn the gas off and replace the test point screw. Turn the gas on and check the test point for gas soundness.

5.CLOSURE PLATE INSTALLATION

NOTE: The Small & Medium stoves are also suitable for installation onto a fireplace opening. The following method illustrates how this can be achieved with the aid of the optional closure plate and spigot extension. Ensure the fireplace dimensions are as shown in diagram 4.

5.8Place the closure plate against the fireplace opening and ensure there is sufficient overlap around the perimeter to allow a fume tight seal to be made. Cut straight across the top of the plate if trimming is required.

5.9Seal the plate to the opening and the hearth with a suitable heat resisting material. Ensure that any relief opening at the bottom of the plate is left unobstructed.

5.10Secure the spigot extension to the engine assembly and seal with heat resisting tape or similar. Position the engine assembly ensuring 50mm rear clearance is maintained and then proceed with the installation as detailed in points 3.2 to 3.3 above. See diagram 4.

4

6. FUEL BED ARRANGEMENT

The major ceramic components can be found inside the firebox. Remove the cast iron door using the tool provided and remove all the protective packaging from these components.

NOTE: THE CAST IRON IS HEAVY, TAKE EXTREME CARE WHEN HANDLING.

Refer to ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS in User Instructions section 5.

The loose coals should be arranged as specified in the following steps. Care should be taken to ensure there is sufficient space between the coals to allow flames to pass through.

Small Marlborough and Stockton 6

6.1Place the flame baffle onto the burner and push up against the rear tray lip, see diagram 5.

5

AR0359

13

Image 13
Contents Marlborough & Stockton Coal Effect Stove Range Contents Flue Check Pass Fail Appliance Commissioning ChecklistGAS Check General User InstructionsLighting the Appliance Advice on Handling and disposal of fire ceramics Cleaning the FireTurning the Stove OFF Upgrading Your StoveSmall Marlborough and Stockton Medium Marlborough and Stockton Large Marlborough Gazco Flue Sure System Installation DetailsFlame Failure Device RunningTechnical Specification Installation InstructionsIns Site Requirements Installation of the GAS SupplyFlue and Chimney Requirements Appliance LocationControl Upgrade InstallationSafety Precautions Installation of the StoveClosure Plate Installation AR0361 AR0369 AR0374 Commissioning CommissioningServicing Instructions Servicing / Fault Finding ChartsServicing Requirements Ignition Functional Check Fault Finding ChartsFlame Failure Functional Check Burner Unit Removal Replacing PartsIgnition Lead and Piezo Pilot UnitPiezo GAS Valve Magnetic Safety ValvePrimary Aeration Plate Main InjectorChanging Between GAS Types LPG Short Spares ListService Records Page Page Member of the Stovax Group