Stovax Logic Hotbox & Convector Fire Appliance Commissioning Checklist, Flue Check Pass Fail

Page 3

APPLIANCE COMMISSIONING CHECKLIST

IMPORTANT NOTICE

Explain the operation of the appliance to the end user, hand the completed instructions to them for safe keeping,

as the information will be required when making any guaranteed claims.

FLUE CHECK

 

PASS

FAIL

 

 

 

 

 

1.

Flue is correct for appliance

 

 

 

 

 

 

 

 

2.

Flue flow test

 

 

 

 

 

 

 

 

3.

Spillage test

 

 

 

 

 

 

 

GAS CHECK

 

 

 

 

 

 

 

 

1.

Gas soundness & let by test

 

 

 

 

 

 

 

 

2.

Standing pressure test

 

mb

 

 

 

 

 

 

3.

Appliance working pressure (on High Setting)

 

mb

 

 

NB All other gas appliances must be operating on full

 

 

 

 

 

 

 

 

4.

Gas rate

 

m3/h

 

 

 

 

 

 

5.

Does ventilation meet appliance requirements

 

 

 

 

 

 

 

 

6.

Have controls been upgraded (Upgradeable models only)

8455 Standard

YES

NO

 

 

 

 

 

DEALER AND INSTALLER INFORMATION

Dealer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation Company. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contact No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Engineer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Date of Purchase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contact No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Corgi Reg No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Serial No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Date of Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gas Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Image 3
Contents Logic Hotbox & Convector Fire Contents Appliance Commissioning Checklist Flue Check Pass FailGAS Check User Instructions Arrangement of Fuel BED Components Cleaning the FireCoal Layout from Front ROW Front ROW Coal Layout Using Flat Fire FrontsFront ROW Coal Layout Using Curved Fire Fronts Coal Layout10. ‘RUNNING IN’ Installation DetailsOxygen Depletion Sensor Flame Failure DeviceConvector Installation InstructionsTechnical Specification P8308MCUC GAS CategoryInstallation Instructions Site Requirements Flue and Chimney RequirementsAppliance Location AIR Vents Must not be Restricted GAS SupplyInstallation Cable Retention Method Installation of the ApplianceScrew Fixing Method Coal Layout Front ROW Coal Layout Using Flat Fire Fronts Front ROW Coal Layout Using Curved Fire FrontsCoal Layout from Front ROW AR1173 Commissioning Installation / CommissioningServicing Instructions ServicingServicing Requirements Ignition Functional Check No Spark Ignition Functional Check Pilot will not LightFault Finding Charts ODS Pilot Unit Replacing PartsIgnition Lead PiezoGAS Valve Spares Part Lists MAG UnitMain Injector Changing Between GAS Types

Logic Hotbox & Convector Fire specifications

The Stovax Logic Hotbox and Convector Fire represents a significant advancement in home heating solutions, combining sleek design with efficient performance. This innovative fireplace system offers a modern twist on traditional heating methods, making it a popular choice for homeowners seeking both aesthetics and functionality.

One of the main features of the Stovax Logic Hotbox is its high efficiency rating. Designed to provide a clean and powerful heat output, this fire utilizes advanced combustion technology to ensure that a greater percentage of the fuel is converted into heat. This not only maximizes warm air flow within the home but also minimizes emissions, making it an environmentally responsible choice.

The Hotbox model is equipped with a large glass window that provides an expansive view of the flames, creating a warm and inviting atmosphere. This feature not only enhances the visual appeal of the fire but also enables homeowners to enjoy the relaxing ambiance that a real flame provides. The front-loading design of the fire makes it easy to load fuel, ensuring prolonged burning cycles and reduced maintenance.

The Stovax Logic Convector Fire variant further enhances the heating efficiency through its unique convection technology. This system draws in cool air from the room, circulates it around the fire chamber, and then gently releases the warmed air back into the room. This process ensures that heat is distributed evenly throughout the space, maximizing comfort while reducing energy consumption.

In terms of customization, the Stovax Logic range offers various design options, allowing users to select from different sizes and finishes to match their home décor. With stylish choices ranging from contemporary to more traditional styles, homeowners can integrate the fire seamlessly into their living spaces.

Safety is also a top priority for the Stovax Logic Hotbox and Convector Fire. Equipped with features such as a heat-resistant glass and a secure casing, these fires are designed to perform safely in any home environment.

Overall, the Stovax Logic Hotbox and Convector Fire stand out as an ideal choice for those seeking a combination of elegant design, advanced technology, and efficient heating. Whether you are updating your existing fireplace or considering installing a new one, this innovative solution promises to deliver both comfort and style, making it an intelligent addition to any home.