Westinghouse W-259 owner manual Mounting and Wiring Instructions, Fixture Assembly Instructions

Page 4

12 pg_W-259_EFS 3/10/07 9:23 AM Page 4

MOUNTING AND WIRING INSTRUCTIONS

NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.

1.Turn off power at circuit box to avoid possible electric shock.

2.Remove cap nuts (A) from back plate (B) and remove universal mounting plate or cross bar (C), leaving mounting screws (D) in place (see fig. 1).

3.Secure universal mounting plate or cross bar (C) to outlet box (E) with outlet box screws (F) (not included).

4.Identify color coding of fixture wires (see fig. 2 on page 11).

5.To connect wires, take black fixture wire (group A from fig. 2) and place evenly against black outlet box wire. Do not twist wires.

6.Fit wire connector (G from fig. 1) over wires and twist until there is a firm connection. If wire connector (G) easily comes off, reattach and check again for a firm connection.

7.Repeat steps 5 and 6 with the white (group B from fig. 2) fixture and outlet box wires.

8.Partially thread green grounding screw (H) into side hole (I) on universal mounting plate or cross bar (C) (see fig.1).

9.Wrap ground wire from fixture and ground wire (metal or green wire) from outlet box (E) around green grounding screw (H) on universal mounting plate or cross bar (C).

10.Tighten green grounding screw (H). Do not over tighten.

11.Tuckwires inside outlet box (E) (see fig. 1).

FIXTURE ASSEMBLY INSTRUCTIONS

Warning: This fixture is for indoor use only.

1.Position back plate (B) over mounting screws (D) by aligning back plate openings (J) with mounting screws (D).

NOTE: Position back plate with power switch (K) pointed downward.

2.Secure with cap nuts (A).

3.Install glass shade(s) (L) into holder(s) (M). Secure with thumb screws (N).

4.Install lamp(s) (P) into socket base (O) by inserting and twisting to lock..

5.Turn power back on at circuit box.

4

Image 4
Contents Guide d’utilisation Manual del Usuario Fixture Warranty Information Assembly Instructions for Indoor Light FixtureLamp Warranty Information Holder M Thumb Screws N Lamp P Glass Shade L Socket Base O Mounting and Wiring Instructions Fixture Assembly InstructionsRenseignements sur le remplacement de l’ampoule Westinghouse NON Fourni Instructions DE Montage ET DE Raccordement Instructions D’ASSEMBLAGE DE Lappareil DéclairageInformación sobre la lámpara de repuesto Westinghouse Figura Instrucciones DE Montaje Y Cableado Instrucciones DE Montaje DEL ArtefactoFigura Cleaning and Care Commande DE PiècesOrdering Parts Nettoyage ET Entretien

W-259 specifications

The Westinghouse W-259 is a notable entry in the spectrum of compact and efficient environmental control systems, particularly recognized for its purpose in the commercial and residential sectors. Engineered with cutting-edge features, the W-259 addresses the growing need for sustainable energy solutions without compromising on performance or comfort.

Equipped with advanced heat pump technology, the W-259 excels in providing both heating and cooling capabilities. This versatile system uses a refrigerant cycle to efficiently transfer heat from one area to another, making it an eco-friendly alternative compared to traditional heating systems. Its Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER) ratings are indicative of its ability to significantly reduce energy consumption, helping users save on utility bills while also minimizing their carbon footprint.

One of the standout characteristics of the Westinghouse W-259 is its user-friendly digital control interface. The system incorporates smart technology, enabling users to establish precise temperature settings, program schedules, and monitor energy usage through a smartphone app. This technology promotes greater user engagement and control, allowing individuals to optimize their home environment efficiently.

The W-259 is also designed with noise reduction in mind. Utilizing advanced soundproofing techniques, it operates quietly, making it ideal for residential spaces where peace and tranquility are paramount. Its compact design allows for easy installation in smaller spaces, making it an attractive option for urban dwellings and other constrained environments.

In terms of safety features, the Westinghouse W-259 comes with built-in sensors to detect any anomalies in operation. This proactive approach to safety ensures that the system operates within safe parameters and alerts users in case of any potential issues, providing peace of mind.

Durability is another hallmark of the W-259. Constructed with high-quality materials, this system is built to withstand varying environmental conditions, ensuring long-lasting performance. Its streamlined maintenance requirements further enhance its appeal, making it a practical solution for homeowners and business operators alike.

In summary, the Westinghouse W-259 stands out with its innovative heat pump technology, user-friendly controls, quiet operation, safety features, and robust construction. It represents a forward-thinking approach to environmental control, aligning perfectly with contemporary needs for energy efficiency and sustainability.