Vulcan-Hart GCT36, GCT60 Leveling, GAS Pressure Regulator, GAS Connections, Flue Connections

Page 5

LEVELING

To level the hot plate, place a carpenter's level on the hot plate and check leveling of the unit side to side and front to rear. Achieve leveling by turning each foot section of the unit's leg as needed. Turning the foot in a counter clockwise direction will increase height and clockwise will decrease.

GAS PRESSURE REGULATOR

A preset gas pressure regulator and street elbow is shipped with the hot plate. This regulator must be installed by an authorized service person before the unit is placed into operation. See full unit data plate located on the side of the hot plate, for pressure regulator setting information. If a manometer is being used, utilizing one of the available pressure taps in the manifold, the manifold pressure with one burner on should be ± 0.3" W.C. of the value indicated on the rating plate.

1.Locate the gas connection pipe protruding through the back of the unit.

2.Cover the pipe threads with pipe joint compound resistant to propane gases.

3.Screw the regulator onto the pipe hand tight with flow direction arrow pointing towards the back of the unit and the regulator adjustment in the up right position.

4.With a pipe wrench, tighten the regulator securely in the upright position. (The regulator is preset and should not require any additional adjustments.) The pressure regulator must be mounted horizontally to ensure the proper preset outlet pressure. If mounted in any other direction, the outlet pressure must be rechecked and possibly reset. A leak limiter is supplied with every regulator to allow excess gas pressure to escape. Do not obstruct the limiter or the gas regulator, as obstruction may cause the regulator to malfunction.

GAS CONNECTIONS

All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases.

Prior to lighting, check all joints in the gas supply line for leaks. Use soap and water solution. Do not use an open flame.

After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.

TESTING THE GAS SUPPLY SYSTEM

When test pressures exceed ½ psig (3.45 kPa), the hot plate and its individual shutoff valve must be disconnected from the gas supply piping system.

When test pressures are ½ psig (3.45 kPa) or less, the hot plate must be isolated from the gas supply system by closing its individual manual shutoff valve.

FLUE CONNECTIONS

DO NOT obstruct the flow of flue gases from the flue located on the rear of the hot plate. Proper venting of flue gas is vital to the safe and efficient operation of the hot plate. Problems arising from the intentional obstruction of the flue will result in voiding of warranty. It is recommended that the flue

- 5 -

Image 5
Contents Retain this Manual for Future USE Vulcan Endurance Series Gas Hot PlatesFor Your Safety Important for Your SafetyInstallation Optional Field Installable AccessoriesCaster Equipped HOT Plates Installation Codes and StandardsLeveling Testing the GAS Supply SystemGAS Pressure Regulator GAS ConnectionsOperation CleaningControls Lighting and Shutting Down PilotsMaintenance & Adjustments Problem Causes / Corrections TroubleshootingPrecautions Mode D’INSTALLATION ET Mode D’EMPLOI Mesure DE Sécurité Mesures DE Sécurité ImportantesDescription Accessoires InstallationEmplacement DéballageAux États-Unis Codes D’INSTALLATION ET NormesRégulateur DE Pression DE GAZ NivelageBranchement DU GAZ Essais DE LA Canalisation DE GAZNettoyage CommandesAllumage ET Extinction DES Veilleuses Suggestions DE FonctionnementEntretien ET Réglages Service DE L’ENTRETIEN ET Pièces DE RechangeNettoyage DU Revêtement Extérieur Acier InoxydableProblème Causes Possibles RemarquesPrécautions