Vulcan-Hart C24GA6 ML-136021 Length, End Fittings 1 Quick Disconnect End Fittings Both Threaded

Page 8

C24GA SERIES GAS CONVECTION STEAMERS

Gas Connection Data

FLEXIBLE GAS CONNECTORS BTU/hr. FLOW CAPACITY 1, 2

 

 

LENGTH 3

 

 

LENGTH 3

 

 

End Fittings - (1) Quick Disconnect

End Fittings - Both Threaded

 

 

& (1) Threaded

 

 

 

 

 

ID

36"

48"

60"

72"

36"

48"

60"

72"

½"

77,000

68,000

60,000

55,000

120,000

106,000

93,000

86,000

¾"

218,000

180,000

158,000

139,000

256,000

225,000

198,000

175,000

1"

379,000

334,000

294,000

279,000

512,000

451,000

397,000

350,000

1¼"

615,000

541,000

476,000

419,000

946,000

833,000

733,000

645,000

1.Flow rating BTU/hr. 0.64 SP. GR @ 0.5 inch W.C. pressure drop.

2.BTU/hr. flow capacities are based on Dormont Mfg. Co. Supr-Safe gas line connectors and are provided for reference. Additional quick disconnect fittings, swivels, or manual shut off valves will reduce the BTU/hr. flow capacities listed in this table. If other flexible gas connectors are used, check the manufacturer’s specifications for BTU/hr. flow capacities. Supr-Safe is a registered trademark of the Dormont Manufacturing Company.

3.The maximum length for a flexible gas connector is 72" per National Fuel Code standards.

BLACK IRON PIPE BTU/hr. FLOW CAPACITY 1, 2, 3

Natural Gas

 

Nominal Inside Diameter of Pipe

 

 

Pipe Length

½"

¾"

1"

1¼"

1½"

2"

15'

76,000

172,000

345,000

750,000

1,220,000

2,480,000

30'

52,000

120,000

241,000

535,000

850,000

1,780,000

45'

43,000

99,000

199,000

435,000

700,000

1,475,000

60'

38,000

86,000

173,000

380,000

610,000

1,290,000

75'

 

77,000

155,000

345,000

545,000

1,120,000

90'

 

70,000

141,000

310,000

490,000

1,000,000

1.Flow rating BTU/hr. 0.64 SP. GR @ 0.3 inch W.C. pressure drop.

2.BTU/hr. flow capacities are based on Schedule 40 pipe, include a tolerance for pressure losses in gas piping systems are provided for reference.

3.Count each 90° elbow as 3' of gas pipe for the purpose of calculating total pipe length.

— 8 —

Image 8
Contents Installation C24GA Series GAS Convection Steamers Important for Your Safety For Your SafetyInstallation Installation Codes StandardsIntroduction GeneralLocation GAS Steamers Leveling and AnchoringPlumbing Connections Water TreatmentWater Supply Connection Filter SystemGAS Supply Connection Drain ConnectionAir˚Pressure˚ Adjust˚Screw On˚Side˚of˚ Drip˚Cover Length End Fittings 1 Quick Disconnect End Fittings Both ThreadedTesting the Gas Supply System Flue GAS ExhaustStart UP Electrical ConnectionElectrical Data Operation Lighting and Shutdown InstructionsCompartment Controls FunctionStartup Procedure PreheatingSteaming OperatingCleaning Draining GeneratorCompartments Door GasketsLeave Compartment Doors Open Guidelines for Maintaining Stainless Steel SurfacesFlue MaintenanceScale Related Maintenance Products to be Cooked in Solid Pans Cooking ChartProduct Timer Setting Weight Minutes Products to be Cooked in Perforated Pans Cooking Hints Symptoms Possible Causes Remedy TroubleshootingService and Parts Information Rev B

C24GA10 ML-136022, C24GA10 ML-136057, C24GA6 ML-136056, C24GA6 ML-136021 specifications

The Vulcan-Hart C24GA series, including models C24GA6 ML-136056, C24GA6 ML-136021, C24GA10 ML-136022, and C24GA10 ML-136057, represents a pinnacle of efficiency and performance in commercial cooking equipment. Designed specifically to meet the demanding needs of busy kitchens, these versatile gas ranges are built to provide exceptional service and durability.

One of the standout features of the C24GA series is its powerful burners. With multiple BTU output options, these ranges allow chefs to achieve precise temperatures for various cooking techniques, whether boiling, sautéing, or simmering. The high-efficiency burners are designed to distribute heat evenly across the cookware, ensuring consistent cooking results and reducing the risk of hot spots.

The C24GA models are constructed with robust stainless steel bodies, ensuring not only durability but also ease of cleaning. The polished finish helps maintain a professional look in any kitchen environment. The heavy-duty grates are designed for stability and support, accommodating different sizes of pots and pans. The grates are also dishwasher safe, making maintenance straightforward.

One of the technological advancements featured in the C24GA series is the electronic ignition system. This feature enhances safety by eliminating the need for pilot lights, reducing gas emissions and minimizing the risk of gas buildup. The system provides quick and reliable ignition with a simple turn of the knob, an asset in high-pressure kitchen scenarios.

In terms of configuration, the range is designed with adaptability in mind. The modular design allows for various combinations and configurations tailored to specific kitchen layouts and workflow requirements. Whether it’s integrating with other pieces of equipment or fitting into tight spaces, the C24GA range provides flexibility for chefs and kitchen planners alike.

Moreover, the C24GA series includes easy-to-access controls positioned at the front, allowing chefs to adjust flames effortlessly while monitoring cooking progress. The continuous belt of knobs provides a user-friendly experience, ensuring that meal preparation flows smoothly.

In conclusion, the Vulcan-Hart C24GA6 and C24GA10 models exemplify the attributes essential for any high-volume kitchen. With their durable construction, efficient burners, user-friendly features, and modern technologies, they are an ideal choice for restaurants, caterers, and institutional kitchens seeking reliable performance and versatility in their cooking operations. Investing in a Vulcan-Hart C24GA range is a commitment to quality, efficiency, and the culinary excellence that modern dining demands.