Vulcan-Hart C24GA10 ML-136022, C24GA6 ML-136021 Air˚Pressure˚ Adjust˚Screw On˚Side˚of˚ Drip˚Cover

Page 7

Air˚Pressure˚

Adjust˚Screw

On˚Side˚of˚

Drip˚Cover

Figure 1

The proper sizing and installation of the gas connection is important for the machine to operate within its design specifications. In some installations, the gas supply may not be sufficient enough to allow all the gas equipment to operate properly at peak loads; or when other equipment with a high BTU/hr. input requirement is operating. The connection to the machine becomes even more important in this type of location.

Flexible gas connectors with quick disconnect or swivel fittings (when used) and gas connectors beyond the length necessary will reduce the BTU/hr. flow capacity to the machine.

Note: Do not use corrugated stainless steel tubing for commercial gas equipment supply connections.

Note: A straight gas connection is the ideal condition for the rated BTU/hr. flow capacity of the connector. If a straight connection is not possible and a flexible gas connector is used, do not twist, kink or excessively flex the

C24GA SERIES GAS CONVECTION STEAMERS

connector beyond a U shape. Flexing the gas connector as described will restrict gas flow or may damage the connector.

Changing a flexible gas connector may raise the BTU/hr. flow capacity enough to allow the machine to operate within its design specifications. (i.e. Removing the quick disconnect fitting, installing a shorter gas connector or installing a larger diameter gas connector.)

An alternative may be to move the equipment to a different gas supply location in the kitchen. (i.e. Closer to the main supply into the kitchen or away from other equipment with high BTU/hr. input requirements.)

Figure 3

The generator is equipped with a factory- preset pressure regulator. Natural gas pressure regulators are preset for 2.5" W.C. (0.62 kPa). Propane gas pressure regulators

— 7 —

Image 7
Contents Installation C24GA Series GAS Convection Steamers For Your Safety Important for Your SafetyGeneral InstallationInstallation Codes Standards IntroductionLeveling and Anchoring Location GAS SteamersFilter System Plumbing ConnectionsWater Treatment Water Supply ConnectionDrain Connection GAS Supply ConnectionAir˚Pressure˚ Adjust˚Screw On˚Side˚of˚ Drip˚Cover End Fittings 1 Quick Disconnect End Fittings Both Threaded LengthFlue GAS Exhaust Testing the Gas Supply SystemElectrical Data Electrical ConnectionStart UP Function OperationLighting and Shutdown Instructions Compartment ControlsOperating Startup ProcedurePreheating SteamingDoor Gaskets CleaningDraining Generator CompartmentsGuidelines for Maintaining Stainless Steel Surfaces Leave Compartment Doors OpenScale Related Maintenance MaintenanceFlue Product Timer Setting Weight Minutes Cooking ChartProducts to be Cooked in Solid Pans Products to be Cooked in Perforated Pans Cooking Hints Service and Parts Information TroubleshootingSymptoms Possible Causes Remedy Rev B

C24GA10 ML-136022, C24GA10 ML-136057, C24GA6 ML-136056, C24GA6 ML-136021 specifications

The Vulcan-Hart C24GA series, including models C24GA6 ML-136056, C24GA6 ML-136021, C24GA10 ML-136022, and C24GA10 ML-136057, represents a pinnacle of efficiency and performance in commercial cooking equipment. Designed specifically to meet the demanding needs of busy kitchens, these versatile gas ranges are built to provide exceptional service and durability.

One of the standout features of the C24GA series is its powerful burners. With multiple BTU output options, these ranges allow chefs to achieve precise temperatures for various cooking techniques, whether boiling, sautéing, or simmering. The high-efficiency burners are designed to distribute heat evenly across the cookware, ensuring consistent cooking results and reducing the risk of hot spots.

The C24GA models are constructed with robust stainless steel bodies, ensuring not only durability but also ease of cleaning. The polished finish helps maintain a professional look in any kitchen environment. The heavy-duty grates are designed for stability and support, accommodating different sizes of pots and pans. The grates are also dishwasher safe, making maintenance straightforward.

One of the technological advancements featured in the C24GA series is the electronic ignition system. This feature enhances safety by eliminating the need for pilot lights, reducing gas emissions and minimizing the risk of gas buildup. The system provides quick and reliable ignition with a simple turn of the knob, an asset in high-pressure kitchen scenarios.

In terms of configuration, the range is designed with adaptability in mind. The modular design allows for various combinations and configurations tailored to specific kitchen layouts and workflow requirements. Whether it’s integrating with other pieces of equipment or fitting into tight spaces, the C24GA range provides flexibility for chefs and kitchen planners alike.

Moreover, the C24GA series includes easy-to-access controls positioned at the front, allowing chefs to adjust flames effortlessly while monitoring cooking progress. The continuous belt of knobs provides a user-friendly experience, ensuring that meal preparation flows smoothly.

In conclusion, the Vulcan-Hart C24GA6 and C24GA10 models exemplify the attributes essential for any high-volume kitchen. With their durable construction, efficient burners, user-friendly features, and modern technologies, they are an ideal choice for restaurants, caterers, and institutional kitchens seeking reliable performance and versatility in their cooking operations. Investing in a Vulcan-Hart C24GA range is a commitment to quality, efficiency, and the culinary excellence that modern dining demands.