Vulcan-Hart C24GA6 ML-136056, C24GA6 ML-136021 Flue GAS Exhaust, Testing the Gas Supply System

Page 9

are preset for 10" W.C. (2.46 kPa). No further adjustment should be required. Check gas pressures with a manometer at time of installation to verify that they agree with the pressures specified.

Prior to lighting, check all

joints in the gas supply line for leaks. Use soap and water solution. Do not use an open flame.

A. Check all joints prior to the gas valve (solenoid) before lighting unit.

B. Check all joints beyond gas valve (solenoid) after unit is lit.

After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.

Testing the Gas Supply System

When the gas supply pressure exceeds 1/2 psig (3.45 kPa), the steamer and its individual manual gas shutoff valve must be disconnected from the gas supply piping system.

When the gas supply pressure is ½ psig (3.45 kPa) or less, the steamer should be isolated from the gas supply system by closing its individual manual gas shutoff valve.

C24GA SERIES GAS CONVECTION STEAMERS

FLUE GAS EXHAUST

DO NOT obstruct the flow of flue gases from the flue located on the rear of the steamer.

It is recommended that the flue gases be vented to the outside of the building through a ventilation system installed by qualified personnel.

Information on the construction and installation of ventilating hoods may be obtained from Vapor Removal from Cooking Equipment, NFPA-96 (latest edition) available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

— 9 —

Image 9
Contents Installation C24GA Series GAS Convection Steamers For Your Safety Important for Your SafetyInstallation Codes Standards InstallationIntroduction GeneralLeveling and Anchoring Location GAS SteamersWater Treatment Plumbing ConnectionsWater Supply Connection Filter SystemDrain Connection GAS Supply ConnectionAir˚Pressure˚ Adjust˚Screw On˚Side˚of˚ Drip˚Cover End Fittings 1 Quick Disconnect End Fittings Both Threaded LengthFlue GAS Exhaust Testing the Gas Supply SystemElectrical Connection Electrical DataStart UP Lighting and Shutdown Instructions OperationCompartment Controls FunctionPreheating Startup ProcedureSteaming OperatingDraining Generator CleaningCompartments Door GasketsGuidelines for Maintaining Stainless Steel Surfaces Leave Compartment Doors OpenMaintenance Scale Related MaintenanceFlue Cooking Chart Product Timer Setting Weight MinutesProducts to be Cooked in Solid Pans Products to be Cooked in Perforated Pans Cooking Hints Troubleshooting Service and Parts InformationSymptoms Possible Causes Remedy Rev B

C24GA10 ML-136022, C24GA10 ML-136057, C24GA6 ML-136056, C24GA6 ML-136021 specifications

The Vulcan-Hart C24GA series, including models C24GA6 ML-136056, C24GA6 ML-136021, C24GA10 ML-136022, and C24GA10 ML-136057, represents a pinnacle of efficiency and performance in commercial cooking equipment. Designed specifically to meet the demanding needs of busy kitchens, these versatile gas ranges are built to provide exceptional service and durability.

One of the standout features of the C24GA series is its powerful burners. With multiple BTU output options, these ranges allow chefs to achieve precise temperatures for various cooking techniques, whether boiling, sautéing, or simmering. The high-efficiency burners are designed to distribute heat evenly across the cookware, ensuring consistent cooking results and reducing the risk of hot spots.

The C24GA models are constructed with robust stainless steel bodies, ensuring not only durability but also ease of cleaning. The polished finish helps maintain a professional look in any kitchen environment. The heavy-duty grates are designed for stability and support, accommodating different sizes of pots and pans. The grates are also dishwasher safe, making maintenance straightforward.

One of the technological advancements featured in the C24GA series is the electronic ignition system. This feature enhances safety by eliminating the need for pilot lights, reducing gas emissions and minimizing the risk of gas buildup. The system provides quick and reliable ignition with a simple turn of the knob, an asset in high-pressure kitchen scenarios.

In terms of configuration, the range is designed with adaptability in mind. The modular design allows for various combinations and configurations tailored to specific kitchen layouts and workflow requirements. Whether it’s integrating with other pieces of equipment or fitting into tight spaces, the C24GA range provides flexibility for chefs and kitchen planners alike.

Moreover, the C24GA series includes easy-to-access controls positioned at the front, allowing chefs to adjust flames effortlessly while monitoring cooking progress. The continuous belt of knobs provides a user-friendly experience, ensuring that meal preparation flows smoothly.

In conclusion, the Vulcan-Hart C24GA6 and C24GA10 models exemplify the attributes essential for any high-volume kitchen. With their durable construction, efficient burners, user-friendly features, and modern technologies, they are an ideal choice for restaurants, caterers, and institutional kitchens seeking reliable performance and versatility in their cooking operations. Investing in a Vulcan-Hart C24GA range is a commitment to quality, efficiency, and the culinary excellence that modern dining demands.