9. Installation

INSTRUCTION

HANDBOOK

The gas exchanger is adjusted at the plant to be suitable for the kind of gas specifi ed on the order. If you have to supply your machine with gas in a family different from the gas for which your machine was adjusted, proceed as follows.

Testing pressures

According to the EN 437 standard, the values of the testing pressures mentioned in our various documents are values for static pressure taken at the gas inlet connection of the machine ; the heating of the machine being on.

Changing to a gas in the same family (type H or L)

Change the 3 injectors with joints (see ta- bles of correspondences).

Changing to a gas in a different family (from type H or L to butane or propane)

Change the 3 injectors with joints (see ta- bles of correspondences)

Unscrews the fi xing screws (V) and remove the adjusting head (J) as well as its cork (T), keep these parts in case a change would by necessary.

Replace it by the cork (L) and the plate (P).

Screw the two screws and block.

Changing a gas from one family to another (from butane or propane to type H or L)

Change the 3 injectors with joints (see ta-

D0291

bles of correspondences)

 

Unscrews the fi xing screws (V) and remove the plate (P) as well as the cork (L), keep these parts in case a change would by necessary.

Set the cork (T) and the adjustment head (J).

Screw the two screws and block.