01201138 | 0107 | 13 | 11 | 11. Machine | INSTRUCTION | |
Notice | Date | Page | operation | |||
| HANDBOOK | |||||
|
|
|
|
|
|
To change parameters in the current program step
991 NORMAL 95 °C STD
PROGRAM STEP : MAIN WASH | 1 | |
STEP TIME : | 720 SEC | |
SET TEMPERATURE : | 85 °C | |
ACTUAL TEMPERATURE : | 21 °C | |
REMAINING TIME : | 70 MIN | |
DRUM SPEED : |
| 1000 RPM |
RAPID ADVANCE :
PAUSE
SELECT
During program operation the display will look like this (see section « To start the wash pro- gram »).
Press one or more times …
You can alter the following parameters :
Prewash, Main wash, Rinse, Drain, Soak, Rinse repeat
Length of program step (max. 9998 seconds), heat- ing temperature (max. 97°C (205°F)).
Extract
Length of program step (max. 3600 seconds), ex- traction speed.
991 NORMAL 95 °C STD
PROGRAM STEP : MAIN WASH | 1 | |
STEP TIME : | 720 SEC | |
SET TEMPERATURE : | 85 °C | |
ACTUAL TEMPERATURE : | 21 °C | |
REMAINING TIME : | 70 MIN | |
DRUM SPEED : | 1000 RPM | |
RAPID ADVANCE | : |
|
PAUSE |
|
SELECT
SELECT
1 2 3
4 5 6
7 8 9
0
…to highlight the time re- quired.
Press SELECT.
Use the numeric keys to enter the ew parameter.
ATTENTION
Never program a temperature above to 90°C (195°F).
If you have entered the wrong parameter
Continue pressing numeric keys to overstrike the incor- rect parameter.
Note : always use the same number of digits as used on the display to overstrike the incorrect parameter.
Example :
To change the time for the program step to 30 sec- onds, enter 030 to overstrike the earlier parameter.
SELECT Press SELECT.
WARNING
If you happen to make your own program, you must not input cold water in the cage while this later has a washing bath at 85°C (185°F), with the cage stopped. It is compulsory that the cage turns while letting in cold water.
A bad programming can, in this particular case, be the cause of the break- age of the doors' windows.