01201138 | 0107 | 75 | 11 | 11. Machine | INSTRUCTION | |
Notice | Date | Page | operation | |||
HANDBOOK | ||||||
|
|
|
|
|
|
Information in display :
Function no allowed.
Probable cause :
A function has been selected in the program which cannot be carried out.
Fault-fi nding procedure :
•Check that the function in question is switched on under "Settings".
•Check that the cables for CPU communication, power supply and load cells are connected.
•Check that these cables are all in good condition.
•If any cable is faulty, replace it.
Information in display service program :
Weighing equipment not connected.
Probable cause :
CPU board not communicating with scale unit.
Fault-fi nding procedure :
•Check that the connectors for CPU communication, power supply and load cells are con- nected on the scale unit.
•Check that their cables are all in good condition.
•If any cable is faulty, replace it.