INSTRUCTION

HANDBOOK

11. Machine

01201138

0107

48

11

operation

Notice

Date

Page

 

Calibrate the scale (for machines with weighing equipment installed only)

SERVICE PROGRAM

MAKE A CHOICE :

RESET SCALE TO ZERO

RESET TARE TO ZERO

TARE SCALE

SET TARE TO A CERTAIN VALUE

READ TARE VALUE

CALIBRATE THE SCALE

SELECT

RESET SCALE TO ZERO

RESET TARE TO ZERO

TARE SCALE

SET TARE TO A CERTAIN VALUE

READ TARE VALUE

CALIBRATE THE SCALE

ZERO CALIBRATION

READ VERSION NUMBER

EXIT

SELECT

Press ￿ three times to high- light "SET TARE TO A CER-

TAIN VALUE".

Press SELECT.

Please note :

This function is used only on installation of a new scale unit.

Calibrate the scale

If this calibration has not succeeded you will see an er- ror message equivalent to: "FAILED. PRESS SELECT" on the display. For troubleshooting, see the section "Fault-fi nding, weighing equipment" in the machine manual.

Please note :

The machine must be unladen at the start of calibartion ; i.e. no water or wash load in the drum.

SCALE ADJUSTMENTS

CALIBRATE THE SCALE

PLEASE SET SCALE TO

CALIBRATE MODE

PRESS SELECT

FOR ZERO CALIBRATION

SELECT

Set the calibration switch to calibartion mode.

SELECT Press SELECT.

SCALE ADJUSTMENTS

CALIBRATE THE SCALE

DONE !

PRESS SELECT

SELECT

Calibration mode/normal mode

To gain access to the calibration switch in the scale unit, the lower front panel has to be taken off.

Remove the four screws on the scale unit cover.

Then the calibration switch can be switched between normal mode "ON" and calibration mode "CAL".

ON (normal)

CAL (calibrage)

Calibration switch

Scale unit

4758

SELECT Press SELECT.

Page 117
Image 117
Electrolux WSB4650H, WS4650H, WSB4250H, WS4500H, WSB4350H, WS4350H, WSB4500H Calibrate the scale, Calibration mode/normal mode