INSTRUCTION
HANDBOOK
11. Machine | 01201138 | 0107 | 48 | 11 | |
operation | Notice | Date | Page | ||
|
Calibrate the scale (for machines with weighing equipment installed only)
SERVICE PROGRAM
MAKE A CHOICE :
RESET SCALE TO ZERO
RESET TARE TO ZERO
TARE SCALE
SET TARE TO A CERTAIN VALUE
READ TARE VALUE
CALIBRATE THE SCALE
SELECT
RESET SCALE TO ZERO
RESET TARE TO ZERO
TARE SCALE
SET TARE TO A CERTAIN VALUE
READ TARE VALUE
CALIBRATE THE SCALE
ZERO CALIBRATION
READ VERSION NUMBER
EXIT
SELECT
Press three times to high- light "SET TARE TO A CER-
TAIN VALUE".
Press SELECT.
Please note :
This function is used only on installation of a new scale unit.
Calibrate the scale
If this calibration has not succeeded you will see an er- ror message equivalent to: "FAILED. PRESS SELECT" on the display. For troubleshooting, see the section
Please note :
The machine must be unladen at the start of calibartion ; i.e. no water or wash load in the drum.
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
PLEASE SET SCALE TO
CALIBRATE MODE
PRESS SELECT
FOR ZERO CALIBRATION
SELECT
Set the calibration switch to calibartion mode.
SELECT Press SELECT.
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
DONE !
PRESS SELECT
SELECT
Calibration mode/normal mode
To gain access to the calibration switch in the scale unit, the lower front panel has to be taken off.
Remove the four screws on the scale unit cover.
Then the calibration switch can be switched between normal mode "ON" and calibration mode "CAL".
ON (normal) | CAL (calibrage) |
Calibration switch | Scale unit |
4758
SELECT Press SELECT.