INSTRUCTION

HANDBOOK

11. Machine

01201138

0107

72

11

operation

Notice

Date

Page

Fault-finding, weighing equipment

Error message on display :

Weight, in kg : 999,0 or -999,9

Probable cause :

The weighing equipment is overloaded/ "underloaded", i.e. the load cells are sending a signal which is too high/low to the scale unit. Probable cause is one or more load cells faulty. The dead load selector may be on the wrong setting. The machine may be incorrectly installed.

Fault-fi nding procedure :

Check that all connections to the machine are fl exible.

Fig. • Remove the side panel. Check that the

8dead load selector is set to 580-880 kg (machines 250-350-500) or 830-1130 kg (machine 650). If it is not, set it correctly and calibrate the weighing equipment according to "Calibrate the scale" under "Machine operation".

If the weight displayed is -999.9, try fol- lowing the "Zero calibration" procedure (described under "Zero calibration" in the "Machine operation" chapter).

Remove the side panels and check that the load cells are unobstructed. Remove any mechanical obstructions.

Fig. • Taking the load cell cables one at a time,

8disconnect the cable connecting each load cell to the scale unit. Continue one by one until a stable weight parameter is displayed (but not 999.9). When this sta- ble parameter is displayed you will know which of the load cells must be faulty.

8

Weight-totalling board

Board connectors

Board connectors

Dead load selector

4804

Page 141
Image 141
Electrolux WSB4650H, WS4650H, WSB4250H, WS4500H, WSB4350H, WS4350H, WSB4500H, WS4250H manual Fault-finding, weighing equipment