01201138 | 0107 | 15 | 11 | 11. Machine | INSTRUCTION | |
Notice | Date | Page | operation | |||
| HANDBOOK | |||||
|
|
|
|
|
|
Show weight (for machines with weighing equipment installed only)
991 NORMAL 95 °C STD
PROGRAM STEP : MAIN WASH | 1 | |
STEP TIME : | 720 SEC | |
SET TEMPERATURE : | 85 °C | |
ACTUAL TEMPERATURE : | 21 °C | |
REMAINING TIME : | 70 MIN | |
DRUM SPEED : |
| 1000 RPM |
RAPID ADVANCE :
SHOW WEIGHT
SELECT
STEP TIME
SET TEMPERATURE
RAPID ADVANCE
SHOW WEIGHT
NO WATER REDUCTION
PAUSE
MANUAL FUNCTIONS
TEXT
SELECT NEW WASH PROGRAM
CHANGE °F/°C
AUTO RESTART
During program operation, the display will look like this (see section "To start the wash pro- gram").
Show weight
The actual weight is shown in large digits on the dis- play (weight display mode).
If the weighing equipment is not connected, the error message "FUNCTION NOT ALLOWED" will appear. See the section
SELECT
CLARUS CONTROL
WEIGHT, KG :
097.0
Press or one or more times to highlight « SHOW WEIGHT ».
Press SELECT.
Weight display mode :
The actual net weight is shown in large digits on the display.
Return to normal display
The display will return to normal at the end of the "time for weight display" set as a parameter in Settings 1. The manufacturer’s default parameter is 20 seconds.
To end weight display sooner
Press or use the numeric keys to enter a new program number.