01201138

0108

1

13

13. Maintenance

INSTRUCTION

Notice

Date

Page

 

HANDBOOK

 

 

 

 

 

 

Operating incidents

In order to limit the risk of failure in the electronic controls of the programming unit of the machine, the machine should be earthed. Should interferences happen, the fi rst thing to be checked is the earthing of the machine.

The programming unit permanently checks the machine, regarding both safety and working aspects. To make the fault fi nding easier, the display window indicates in clear text the origin of the failure, or the reason why the particular function cannot be used. The table below gives for each problem detected the message of the machine and the solutions to be brought.

Error/Function

Cause

Action

 

 

- Electrovalve's fi lters are blocked.

- Clean electrovalve's fi lters.

NO WATER

Error 1

 

 

 

 

- No water in main supply.

- Check water in main supply.

Water level has not reacher set

level within set time.

- Manual water valves (taps) are close.

- Open taps.

 

 

 

 

- Electrovalves are faulty.

- Check function of electrovalves.

 

 

- Drain valve is open.

- Check function of drain valve.

 

 

- Check that level tube is sound

 

 

- Level tube is faulty or not come loose from mother

 

 

board.

and his raccordement.

 

 

- Level detection function on CPU PCB faulty.

- Replace PCB.

DOOR OPEN

Error 2

 

 

 

 

 

 

 

 

 

Error 3

 

 

DOOR UNLOCKED

 

 

 

 

 

 

 

Signal from microswitch which

- Door not locked.

- Test whether door really locked.

detects when the door is locked

 

- Open the door and switch off

absent at program start.

- Fault in door lock switch or in wiring faulty.

power to machine. Wait a minute

 

 

 

 

or so, switch on power supply

 

 

 

 

,close door again and try restart-

 

 

 

 

ing.

 

 

 

 

- Check wiring or replace door

 

 

 

 

lock as appropriate.

 

 

 

- The PCB is faulty.

- Replace PCB.

NTC LOW TEMP. Error 4

Temperature sensor indicating a temperature below lowest allow- able value.

- This suggests open circuit (continuity fault) in sen- sor or wiring.

-Check the wiring temperature sensor and replace as appropri- ate.

- Temperature sensor faulty.

- Replace temperature sensor.

- Fault in temperature sensing device on CPU PCB. - Replace PCB.

Page 148
Image 148
Electrolux WS4350H, WS4650H, WSB4250H, WS4500H, WSB4350H Maintenance, Operating incidents, No Water, Door Open, Door Unlocked