01201138

0107

22

Notice Date Page

9

9. Installation

INSTRUCTION

HANDBOOK

TABLE OF CORRESPONDENCES - Washer-Extractor 500

Category Type

Working

 

Ø of

Pressure at

Heat

Consumption

Consumption

of gas

supply

Hi

injectors

injectors

emission

Mn in

Vn in

index

pressure

 

in mm

in mm H2O

Qn in kW

kg/h (Hi)**

m³/h**

 

in mbar

 

 

 

(Hi)

 

 

*2E, 2H,

G 20

20

34.02

2.90

153

40

-

1.90

2ESI

 

 

MJ/m³

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2L, 2ESI

G25

25

29.25

3.20

154

40

-

2.10

 

 

 

MJ/m³

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 P

G31

37

46.34

1.85

regulator out

40

1.40

-

 

 

 

MJ/kg

 

of operation

 

 

 

 

 

 

 

 

 

 

 

 

3 P

G31

50

46.34

1.70

regulator out

40

1.40

-

 

 

 

MJ/kg

 

of operation

 

 

 

* For Belgium, no work is allowed between G20 and G25.

**normal cycle : prewash 3 min at 35 °C, drain. 2 min, main wash 4 min at 65 °C, drain 2 min, rinse 2 min, extract. 2 min, rinse 2 min, extract 2 min, rinse 2 min, extrac. 10 min (cold water supply at 15 °C).

TABLE OF CORRESPONDENCES - Washer-Extractor 650

Category Type

Working

 

Ø of

Pressure at

Heat

Consumption

Consumption

of gas

supply

Hi

injectors

injectors

emission

Mn in

Vn in

index

pressure

 

in mm

in mm H2O

Qn in kW

kg/h (Hi)**

m³/h**

 

in mbar

 

 

 

(Hi)

 

 

*2E, 2H,

G 20

20

34.02

2.90

153

40

-

2.80

2ESI

 

 

MJ/m³

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2L, 2ESI

G25

25

29.25

3.20

154

40

-

3.30

 

 

 

MJ/m³

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 P

G31

37

46.34

1.85

regulator out

40

2.05

-

 

 

 

MJ/kg

 

of operation

 

 

 

 

 

 

 

 

 

 

 

 

3 P

G31

50

46.34

1.70

regulator out

40

2.05

-

 

 

 

MJ/kg

 

of operation

 

 

 

* For Belgium, no work is allowed between G20 and G25.

**normal cycle : prewash 3 min at 35 °C, drain. 2 min, main wash 4 min at 65 °C, drain 2 min, rinse 2 min, extract. 2 min, rinse 2 min, extract 2 min, rinse 2 min, extrac. 10 min (cold water supply at 15 °C).

Note : G20

(H) = natural gas, Lacq type (20 mbar)

G25

(L) = natural gas, Groningue type (20 or 25 mbar)

G31

= propane gas (28/30, 37, 50 mbar)

20 mbar = 0.29 psi

25 mbar = 0.36 psi

28 mbar = 0.41 psi

30 mbar = 0.43 psi

50 mbar = 0.72 psi