INSTRUCTION
HANDBOOK
8.Technical
characteristics
01201138 | 0208 | 16 |
|
|
|
Notice | Date | Page |
|
|
|
8
Washer extractor type 650 barrier |
| Diagram no. 07100088B | ||||
Heating |
|
| Gas | Electric | Steam | Thermic fluid |
Characteristics | Ø cage |
|
| |||
| Cage length |
|
| |||
| Cage volume |
|
| |||
| Specifi c load 1/10 |
| ||||
| (dry linen, ISO | 2x600 x 400 mm (23.62x15.74") | ||||
| Opening cage doors (L x H) | |||||
| Opening drum door (L x H) | 2x616 x 525 mm (24.25x20.66") | ||||
Floor area |
|
|
| |||
Net weight |
|
|
| |||
Weight loaded (high level) |
| 200 l | 200 l | |||
Water, washing, low level |
| 200 l | 200 l | |||
Water, washing, high level |
| 400 l | 400 l | 365 l | 400 l | |
Max dynamic load |
|
|
| |||
Max transmitted floor load |
|
| ||||
Max pressure transmitted to floor |
|
| ||||
Spin efficiency |
|
|
| 350 G | ||
Max. unbalance |
|
|
| 8 kg (17.65 lb) | ||
(L) Main switch to connect main cable | 4x2.5 mm² | 4x35 mm² | 4x2.5 mm² | 4x2.5 mm² | ||
(M) Electric cable (section) |
| |||||
(N) or (N') Stuffing box for main cable |
| |||||
Supply voltage |
|
| ||||
Installed electric power |
| 61.5 kW | 7.8 kW | 7.8 kW | ||
Installed heating power |
| 40 kW | 54 kW | - | - | |
Electrical consumption for a normal cycle* 2 kWh/h | 23 kWh/h | 2 kWh/h | 2 kWh/h | |||
Heat loss |
|
| ||||
(G) Steam inlet | Standard : | DN 20 (3/4" BSP) | Low pressure : DN 25 (1" BSP) |
| ||
| - Maximum supply pressure |
| 600 kPa (87 psi) |
| ||
| - Steam instantaneous fl ow rate at 600 kPa | 216 kg/h |
| |||
| - Steam consumption for a normal cycle* | 24.5 kg/h at 600 kPa (87 psi) | ||||
(D) Hot water connection / flow |
|
| DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi) | |||
(E) Cold hard water connection / flow |
| DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi) | ||||
(F) Cold soft water connection / flow (option) | DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi) | |||||
Water supply minimum pressure |
|
| ||||
Water supply maximum pressure |
| 977 l | 977 l | |||
Water consumption for a normal cycle* | 977 l | 977 l | ||||
Water consumption for an ECO cycle** | 782 l | 782 l | 782 l | 782 l | ||
(K) Liquid detergents inlet |
|
| DN 20 (3/4" BSP) |
|
| |
(H1) Drain connection |
|
| Ø 75 mm (3") | |||
(H2) Double drain connection |
| 240 l/min | Ø 75 mm (3") | 240 l/min | ||
Maximum drain flow rate |
| 240 l/min | ||||
(I) Waste water collector |
|
| ||||
(3 cm/m (3 %) minimum slope) |
|
|
| Ø 60 mm (2.36") | ||
(J) Air vent hole |
|
|
| |||
(N') Thermic fluid inlet or indirect steam heating |
| DN 15 (1/2" BSP) | ||||
(G) Thermic fluid return or indirect steam heating |
| DN 15 (1/2" BSP) | ||||
| - Maximum supply pressure |
|
| 600 kPa | ||
| - Installed calorifi c power |
|
| 47300 kcal | ||
| - Average calorifi c consumption |
|
| 15800 kcal/h | ||
Gas inlet | - Inner volume thermic fl uid | DN 20 (3/4" BSP) |
| 5,33 l | ||
|
|
|
|
| ||
Combustion products evacuation |
|
| Ø 125 mm (5") |
|
|
(O)Barrier partition (provided by customer)
(P)Frame 60x100 mm maxi (provided by customer)
(R)Aseptis seal
(S) Weighing equipment (optional) | Ø 4/6 mm |
Compressed air inlet (low pressure steam) | |
- Min./max. compress air pressure | 5,5/7 |
- Consumption-------------------------------- | 10 |
*normal cycle : prewash 3 min at 35 °C, drain. 2 min, main wash 4 min at 65 °C, drain 2 min, rinse 2 min, extract. 2 min, rinse 2 min, ex- tract 2 min, rinse 2 min, extrac. 10 min (cold water supply at 15 °C).
** ECO cycle : normal cycle with rinse 5 l/kg instead of 6 l/kg dry linen.