INSTRUCTION
HANDBOOK
8.Technical
characteristics
01201138 | 0208 | 2 |
|
|
|
Notice | Date | Page |
|
|
|
8
Washer extractor type 250 standard | Diagram no. 07100081B | |||||
Heating |
| Gas |
| Electric | Steam | Thermic fluid |
Characteristics | Ø cage |
| 770 mm (30.31") | |||
| Cage length |
| 520 mm (20.47") | |||
| Cage volume |
| 229 dm³ (229 l) | |||
| Specifi c load 1/10 | 22.9 kg (50.5 lb) | ||||
| (dry linen, ISO | 450 x 400 mm (17.71x15.74") | ||||
| Opening cage doors (L x H) |
| ||||
| Opening drum door (L x H) | 466 x 525 mm (18.34x20.67") | ||||
Floor area |
|
| 1 m² (10.76 sq. ft) | |||
Net weight |
|
| 670 daN (1478 lb) | |||
Weight loaded (high level) |
| 830 daN (1830 lb) | ||||
Water volume, washing, low level |
| 68 l | ||||
Water volume, washing, high level | 137 l |
| 137 l | 137 l | 137 l | |
Max dynamic load |
| |||||
Max transmitted floor load |
| |||||
Max pressure transmitted to floor |
| |||||
Spin efficiency |
|
| 350 G | |||
Max. unbalance |
|
| 3.6 kg (7.94 lb) | |||
(L) Main switch to connect main cable | 4x2.5 mm² |
| 4x6 mm² | 4x2.5 mm² | 4x2.5 mm² | |
(M) Electric cable (section) |
| |||||
(N) or (N') Stuffing box for main cable |
|
| ||||
Supply voltage |
|
| ||||
Installed electric power |
| 21.7 kW | 3.7 kW | 3.7 kW | ||
Installed heating power | 40 kW |
| 18 kW | - | - | |
Electric consumption for a normal cycle* 0.8 kWh/h | 6 kWh/h | 0.6 kWh/h | 0.6 kWh/h | |||
Heat loss |
|
| ||||
(G) Steam inlet | Standard : DN 20 (3/4" BSP) |
| Low pressure : DN 25 (1" BSP) |
| ||
| - Maximum supply pressure |
|
| 600 kPa (87 psi) |
| |
| - Steam intantaneous fl ow rate at 600 kPa | 72 kg/h |
| |||
| - Seam consumption for a normal cycle* | 12 kg/h at 600 kPa (87 psi) | ||||
(D) Hot water connection / flow |
| DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi) | ||||
(E) Cold hard water connection / flow |
| DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi) | ||||
(F) Cold soft water connection / flow (option) | DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi) | |||||
Water supply minimum pressure |
| 50 kPa (7.25 psi) | ||||
Water supply maximum pressure |
| 300 kPa (43.5 psi) | ||||
Water consumption for a normal cycle* |
| 340 l | 340 l | |||
Water consumption for an ECO cycle** | 282 l |
| 260 l | 260 l | 260 l | |
(K) Liquid detergents inlet |
|
| DN 20 (3/4" BSP) |
|
| |
(H1) Drain connection |
| Ø 75 mm (3") | ||||
(H2) Double drain connection |
| Ø 75 mm (3") | ||||
Maximum flow rate |
| 240 l/min | ||||
(I) Waste water collector |
| |||||
(3 cm/m (3%) minimum slope) |
|
|
| |||
(J) Air vent hole |
|
| ||||
(N') Thermic fluid inlet or indirect steam heating |
|
| DN 15 (1/2" BSP) | |||
(G) Thermic fluid return or indirect steam heating |
|
| DN 15 (1/2" BSP) | |||
| - Maximum supply pressure |
|
|
| 600 kPa | |
| - Installed calorifi c power |
|
|
| 34400 kcal | |
| - Average calorifi c consumption |
|
|
| 11500 kcal/h | |
| - Inner volume thermic fl uid exchanger |
| 2,62 l | |||
Gas inlet |
|
|
| DN 20 (3/4" BSP) |
|
|
Combustion products evacuation |
|
| Ø 125 mm (5") |
|
| |
(S) Weighing equipment (optional) | Ø 4/6 mm |
| ||||
Compressed air inlet (low pressure steam) |
| |||||
| - Min./max. compress air pressure | 5,5/7 | ||||
| - Consumption |
| 10 |
*normal cycle : prewash 3 min at 35 °C, drain. 2 min, main wash 4 min at 65 °C, drain 2 min, rinse 2 min, extract. 2 min, rinse 2 min, ex- tract 2 min, rinse 2 min, extrac. 10 min (cold water supply at 15 °C).
** ECO cycle : normal cycle with rinse 5 l/kg instead of 6 l/kg dry linen.