INSTRUCTION
HANDBOOK
11. Machine | 01201138 | 0107 | 42 | 11 | |
operation | Notice | Date | Page | ||
|
Scale adjustments (for machines with weighing equipment installed only)
SERVICE PROGRAM
MAKE A CHOICE :
SERVICE PROGRAM CLEAR COUNTER CLEAR SERVICE COUNTER CLEAR WASH COUNTER IN PCS
CLEAR WASH COUNTER IN MEMORY CARD SCALE ADJUSTMENTS
SELECT
SELECT
SERVICE PROGRAM
CLEAR COUNTER
CLEAR SERVICE COUNTER
CLEAR WASH COUNTER IN PCS
CLEAR WASH COUNTER IN MEMORY CARD SCALE ADJUSTMENTS
EXIT
Press repeatedly until
SCALE ADJUSTMENTS is highlighted.
Press SELECT.
When you have fi nished :
Press repeatedly until EXIT is highlighted.
Scale adjustments
The following functions are accessed via the SCALE ADJUSTMENTS menu :
Reset scale to zero (see section "Reset scale to zero")
Used to make the weighing equipment display 0 when the machine has no load in it.
Reset tare to zero (see section "Reset tare to zero")
Used to clear a stored tare parameter.
Tare scale (see section "Tare scale")
Used to reset the weighing equipment so that a weight such as a container will not be included when calculating net weight.
Set tare to a certain value (see section "Set tare to a certain value")
Used to enter a value for the tare parameter, a weight in hectograms.
Read tare value (see section "Read tare value") Used to check the value currently stored as the tare parameter.
SELECT Press SELECT.
Calibrate the scale (see section "Calibrate the scale")
This function is used only on installation of a new scale unit.
Zero calibration (see section "Zero calibration") Used to increase the accuracy of the weighing equip- ment.
Read version number (see section "Read version number")
This is where you fi nd the version number of the weighing equipment.
If the weighing equipment is not connected, the error message "WEIGHING EQUIPMENT NOT CON- NECTED" will be displayed. Connect the weigh- ing equipment and try again. If necessary, see the section