INSTRUCTION
HANDBOOK 9. Installation
Gas connection
CAUTION
The installation, connection and gas arrival adjustments for the machine
must be done by qualifi ed personnel only.
The customer must install a fi lter and a manual stop valve on the supply side of the ma-
chine if NATURAL GAS is used.
For BUTANE 28-30 mbar or PROPANE 37 or 50 mbar, the customer must install a fi lter, a
manual closing valve and a pressure reducer.
Check that the diameter of injectors is adequate for the king of gas of your installation (see
table). The machine is delivered with extra injectors in a plastic envelope. There is also a sheet
metal plate with a cork joint or an adjusting head to feed the machine with another gas.
Connect the installation at the exchanger : DN 20 (3/4" BSP).
A : gas burner B : ignition and control electrodes
C : ignitor D : injectors
E : gas admission