INSTRUCTION

HANDBOOK

13. Maintenance

01201138

0108

6

13

Notice

Date

Page

 

 

 

 

 

 

Error

Meaning

Possible cause

Displayed advertisement :

- Voltage in the DC-link circuit too high.

- Poor controller adjustment

 

 

 

(overshooting), input voltage too

KEB ERROR 31 EOP

 

 

high, interference voltages at

 

 

 

the input, deceleration ramp too

Error overvoltage.

 

 

short, braking resistor defective

 

 

 

 

 

 

or too small.

 

 

 

 

Displayed advertisement : - Occurs, if DC-link voltage falls below the permissi- ble value.

KEB ERROR 32 EUP

Error underpotential.

- Input voltage too low or ins- table, inverter rating too small, voltage losses through wrong cabling, the supply voltage through generator/transformer breaks down at very short ramps, E.UP is also displayed if no com- munication takes place between power circuit and control card, jump factor (Pn.56) too small, if a digital input was programmed as external error input with error message E.UP (Pn.65).

Displayed advertisement :

 

- One phase of the input voltage is missing (ripple-

.

 

 

 

 

detection).

 

KEB ERROR 33 EUPH

 

 

 

Error phase failure.

 

 

 

 

 

 

 

 

 

Displayed advertisement :

 

- Occurs, if the specifi ed peak current is exceeded.

- Acceleration ramps too short,

 

 

 

 

 

the load is too big at turned off

KEB ERROR 34 EOC

 

 

 

 

acceleration stop and turned off

 

 

 

 

 

constant current limit, short-cir-

Error overcurrent.

 

 

 

 

cuit at the output, ground fault,

 

 

 

 

 

 

 

 

 

 

deceleration ramp too short,

 

 

 

 

 

motor cable too long, EMC, DC

 

 

 

 

 

brake at high ratings active.

 

 

 

 

Displayed advertisement :

 

- Overheating in the interior : error can only be reset .

 

 

 

 

at E.nOHI, if the interior temperature has dropped

 

KEB ERROR 36 EOHI

 

 

by at least 3°C.

 

 

 

 

 

 

Error overheat internal.

 

 

 

 

 

 

Displayed advertisement :

 

- No longer overheating in the interior E.OHI, interior .

 

 

 

 

temperature has fallen by at least 3°C.

 

KEB ERROR 37 ENOHI

 

 

 

No Error overheat internal.

 

 

 

 

 

 

 

Displayed advertisement :

 

- Overtemperature of power module. Error can only

- Insuffi cient air fl ow at the heat

 

 

 

 

be reset at E.nOH.

sink (soiled), ambient tempera-

KEB ERROR 38 EOH

 

 

 

ture too high, ventilator clogged.

Error overheat pow. mod.

 

 

 

 

 

 

 

Displayed advertisement :

 

- Overtemperature of motor PTC. Error can only be

- Resistance at the terminals

 

 

 

 

reset at E.ndOH, if PTC is again low-resistance.

T1/T2>1650 Ohm, motor over-

KEB ERROR 39 EDOH

 

 

loaded, line breakage to the

 

 

 

 

 

temperature sensor.

Error drive overheat.

 

 

 

 

 

 

 

 

 

 

 

Page 153
Image 153
Electrolux WSB4250H, WS4650H, WS4500H, WSB4350H, WS4350H, WSB4650H, WSB4500H, WS4250H manual KEB Error 31 EOP, KEB Error 32 EUP