INSTRUCTION
HANDBOOK
13. Maintenance | 01201138 | 0108 | 6 | 13 | |
Notice | Date | Page | |||
| |||||
|
|
|
|
|
Error | Meaning | Possible cause | |
Displayed advertisement : | - Voltage in the | - Poor controller adjustment | |
|
|
| (overshooting), input voltage too |
KEB ERROR 31 EOP |
|
| high, interference voltages at |
|
|
| the input, deceleration ramp too |
Error overvoltage. |
| ||
| short, braking resistor defective | ||
|
|
| |
|
|
| or too small. |
|
|
|
|
Displayed advertisement : - Occurs, if
KEB ERROR 32 EUP
Error underpotential.
- Input voltage too low or ins- table, inverter rating too small, voltage losses through wrong cabling, the supply voltage through generator/transformer breaks down at very short ramps, E.UP is also displayed if no com- munication takes place between power circuit and control card, jump factor (Pn.56) too small, if a digital input was programmed as external error input with error message E.UP (Pn.65).
Displayed advertisement : |
| - One phase of the input voltage is missing (ripple- | . | ||
|
|
|
| detection). |
|
KEB ERROR 33 EUPH |
|
|
| ||
Error phase failure. |
|
|
| ||
|
|
|
|
|
|
Displayed advertisement : |
| - Occurs, if the specifi ed peak current is exceeded. | - Acceleration ramps too short, | ||
|
|
|
|
| the load is too big at turned off |
KEB ERROR 34 EOC |
|
|
|
| acceleration stop and turned off |
|
|
|
|
| constant current limit, |
Error overcurrent. |
|
| |||
|
| cuit at the output, ground fault, | |||
|
|
|
|
| |
|
|
|
|
| deceleration ramp too short, |
|
|
|
|
| motor cable too long, EMC, DC |
|
|
|
|
| brake at high ratings active. |
|
|
|
| ||
Displayed advertisement : |
| - Overheating in the interior : error can only be reset . | |||
|
|
|
| at E.nOHI, if the interior temperature has dropped |
|
KEB ERROR 36 EOHI |
|
| by at least 3°C. |
| |
|
|
|
|
| |
Error overheat internal. |
|
|
| ||
|
|
| |||
Displayed advertisement : |
| - No longer overheating in the interior E.OHI, interior . | |||
|
|
|
| temperature has fallen by at least 3°C. |
|
KEB ERROR 37 ENOHI |
|
|
| ||
No Error overheat internal. |
|
|
| ||
|
|
|
| ||
Displayed advertisement : |
| - Overtemperature of power module. Error can only | - Insuffi cient air fl ow at the heat | ||
|
|
|
| be reset at E.nOH. | sink (soiled), ambient tempera- |
KEB ERROR 38 EOH |
|
|
| ture too high, ventilator clogged. | |
Error overheat pow. mod. |
|
|
| ||
|
|
|
| ||
Displayed advertisement : |
| - Overtemperature of motor PTC. Error can only be | - Resistance at the terminals | ||
|
|
|
| reset at E.ndOH, if PTC is again | T1/T2>1650 Ohm, motor over- |
KEB ERROR 39 EDOH |
|
| loaded, line breakage to the | ||
|
|
|
|
| temperature sensor. |
Error drive overheat. |
|
| |||
|
|
| |||
|
|
|
|
|
|