INSTRUCTION
HANDBOOK
9. Installation | 01201138 | 1107 | 11 | 9 | |
Notice | Date | Page | |||
|
Steam and condensate connections: indirect steam heating
Steam connection
The customer must install a line purge, a manually closing valve with handwheel lockable in off position (do not use a 1/4 turn valve) and a fi lter on the supply side of the
Hereunder values apply to the steam pressure.
Recommended pressure : 300 at 600 kPa (3 at 6 kg/cm²) (43.5 at 87 psi)
Limiting of values :
•mini. 100 kPa (1 kg/cm²) (14.5 psi)
•maxi. 600 kPa (6 kg/cm²) (87psi) Connection size : DN 15 (½" BSP).
Condensate connection
The customer must install a steam trap with fl oat closed with an incondensibles drainage device, a
Connection size : DN 15 (½" BSP).
Connect the steam installation on the top of the machine (see example sketch).
A
BLine trap (provided by customer) C Return of condensates
D Manual stop wheel valve (provided by customer)
E Steam fi lter (provided by customer) F Steam trap (provided)
H
M Pressure gauge (provided by customer)
N Thermal insulation for the pipework (provided by customer)
P Steam electrovalve (provided)
S Safety valve (provided by customer) V Steam inlet
D1524