0208 6 8

Notice Date Page
01201138
INSTRUCTION
HANDBOOK
Washer extractor type 500 standard Diagram no. 07100085B
8.Technical
characteristics
Heating Gas Electric Steam Thermic uid
Characteristics Ø cage ---- ----------------------- 770 mm (30.31") -----------------
Cage length ---- ------------------------- 1040 mm (41") -----------------
Cage volume ----------------------- 467 dm³ (467 l) ------------------
Specifi c load 1/10 ---- ----------------------- 46.7 kg (103 lb) ------------------
(dry linen, ISO 9398-4)
Opening cage doors (L x H) ---- ------------ 2x450 x 400 mm (17.71x15.74") ---------
Opening drum door (L x H) ----- ------------- 935 x 527 mm (36.81x20.74") ----------
Floor area ---- -------------------- 1.52 m² (16.36 sq. ft) --------------
Net weight ---- ----------------------- 920 daN (2028 lb) ---------------
Weight loaded (high level) ---- ----------------------- 1247 daN (2750 lb) -------------
Water, washing, low level 140 l 140 l 140 l 140 l
Water, washing, high level 180 l 180 l 180 l 180 l
Max dynamic load ---- ----------------- F = 275 daN (606 lb) ------------------
Max transmitted fl oor load ---- ------------------- 830 daN (1830 lb) -----------------
Max pressure transmitted to fl oor ---- ------------------- 150 kPa -------------------------------
Spin effi ciency ---- ------------------------------ 350 G -----------------------
Max. unbalance ---- ----------------------- 5.5 kg (12.13 lb) -----------------
(L) Main switch to connect main cable
(M) Electric cable (section) 4x2.5 mm² 4x25 mm² 4x2.5 mm² 4x2.5 mm²
(N) or (N') Stuffi ng box for main cable
Supply voltage --------- ----------------380 / 415 V 3+E ~ 50/60 Hz-----------
Installed electric power 5.8 kW 42 kW 5.8 kW 5.8 kW
Installed heating power 40 kW 36 kW - -
Electrical consumption for a normal cycle* 1.5 kWh/h 11 kWh/h 1.2 kWh/h 1.2 kWh/h
Heat loss --------- ----------3 % of installed heating power--------------
(G) Steam inlet Standard : DN 20 (3/4" BSP) Low pressure : DN 25 (1" BSP)
- Maximum supply pressure 600 kPa (87 psi)
- Steam instantaneous fl ow rate at 600 kPa 144 kg/h
- Steam consumption for a normal cycle* 24.5 kg/h at 600 kPa (87 psi)
(D) Hot water connection / fl ow DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi)
(E) Cold hard water connection / fl ow DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi)
(F) Cold soft water connection / fl ow (option) DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi)
Water supply minimum pressure --- ------------------------ 50 kPa (7.25 psi) ---------------
Water supply maximum pressure --- ------------------------ 300 kPa (43.5 psi) --------------
Water consumption for a normal cycle* 638 l 610 l 610 l 610 l
Water consumption for an ECO cycle** 558 l 530 l 530 l 530 l
(K) Liquid detergents inlet DN 20 (3/4" BSP)
(H1) Drain connection --- ------------------------ Ø 75 mm (3") --------------------
(H2) Double drain connection ---
------------------------ Ø 75 mm (3") --------------------
Maximum drain fl ow rate 240 l/min 240 l/min 240 l/min 240 l/min
(I) Waste water collector ---- -------------------- DN 150 mm (6" BSP) ---------------
(3 cm/m (3 %) minimum slope)
(J) Air vent hole ---- -------------------- Ø 60 mm (2.36 ") -------------------
(N') Thermic fl uid inlet or indirect steam heating DN 15 (1/2" BSP)
(G) Thermic fl uid return or indirect steam heating DN 15 (1/2" BSP)
- Maximum supply pressure 600 kPa
- Installed calorifi c power 47300 kcal
- Average calorifi c consumption 13800 kcal/h
- Inner volume thermic fl uid 5,33 l
Gas inlet DN 20 (3/4" BSP)
Combustion products evacuation Ø 125 mm (5")
(S) Weighing equipment (optional)
Compressed air inlet (low pressure steam) ---------------------------Ø 4/6 mm-----------------------------
- Min./max. compress air pressure -------------------5,5/7 bar--------------------------------
- Consumption --------------------------------10 l/h-----------------------------
* normal cycle : prewash 3 min at 35 °C, drain. 2 min, main wash 4 min at 65 °C, drain 2 min, rinse 2 min, extract. 2 min, rinse 2 min, ex-
tract 2 min, rinse 2 min, extrac. 10 min (cold water supply at 15 °C).
** ECO cycle : normal cycle with rinse 5 l/kg instead of 6 l/kg dry linen.