INSTRUCTION
HANDBOOK
8.Technical
characteristics
01201138 | 0208 | 6 |
|
|
|
Notice | Date | Page |
|
|
|
8
Washer extractor type 500 standard |
| Diagram no. 07100085B | |||||
Heating |
|
| Gas |
| Electric | Steam | Thermic fluid |
Characteristics | Ø cage |
| 770 mm (30.31") | ||||
| Cage length |
| 1040 mm (41") | ||||
| Cage volume |
| 467 dm³ (467 l) | ||||
| Specifi c load 1/10 | 46.7 kg (103 lb) | |||||
| (dry linen, ISO | 2x450 x 400 mm (17.71x15.74") | |||||
| Opening cage doors (L x H) |
| |||||
| Opening drum door (L x H) | 935 x 527 mm (36.81x20.74") | |||||
Floor area |
|
| 1.52 m² (16.36 sq. ft) | ||||
Net weight |
|
| 920 daN (2028 lb) | ||||
Weight loaded (high level) |
| 140 l | 1247 daN (2750 lb) | ||||
Water, washing, low level |
|
| 140 l | 140 l | |||
Water, washing, high level |
| 180 l |
| 180 l | 180 l | 180 l | |
Max dynamic load |
| F = 275 daN (606 lb) | |||||
Max transmitted floor load |
| 830 daN (1830 lb) | |||||
Max pressure transmitted to floor |
| 150 kPa | |||||
Spin efficiency |
|
| 350 G | ||||
Max. unbalance |
|
| 5.5 kg (12.13 lb) | ||||
(L) Main switch to connect main cable | 4x2.5 mm² |
| 4x25 mm² | 4x2.5 mm² | 4x2.5 mm² | ||
(M) Electric cable (section) |
|
| |||||
(N) or (N') Stuffing box for main cable |
| 380 / 415 V 3+E ~ 50/60 Hz | |||||
Supply voltage |
|
|
| ||||
Installed electric power |
|
| 42 kW | 5.8 kW | 5.8 kW | ||
Installed heating power |
| 40 kW |
| 36 kW | - | - | |
Electrical consumption for a normal cycle* 1.5 kWh/h | 11 kWh/h | 1.2 kWh/h | 1.2 kWh/h | ||||
Heat loss |
|
| 3 % of installed heating | ||||
(G) Steam inlet | Standard : | DN 20 (3/4" BSP) |
| Low pressure : DN 25 (1" BSP) |
| ||
| - Maximum supply pressure |
|
| 600 kPa (87 psi) |
| ||
| - Steam instantaneous fl ow rate at 600 kPa | 144 kg/h |
| ||||
| - Steam consumption for a normal cycle* | 24.5 kg/h at 600 kPa (87 psi) | |||||
(D) Hot water connection / flow |
|
| DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi) | ||||
(E) Cold hard water connection / flow |
| DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi) | |||||
(F) Cold soft water connection / flow (option) | DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi) | ||||||
Water supply minimum pressure |
| 50 kPa (7.25 psi) | |||||
Water supply maximum pressure |
| 610 l | 300 kPa (43.5 psi) | ||||
Water consumption for a normal cycle* |
| 610 l | 610 l | ||||
Water consumption for an ECO cycle** | 558 l |
| 530 l | 530 l | 530 l | ||
(K) Liquid detergents inlet |
|
| DN 20 (3/4" BSP) |
|
| ||
(H1) Drain connection |
| Ø 75 mm (3") | |||||
(H2) Double drain connection |
| 240 | 240 l/min | Ø 75 mm (3") | 240 l/min | ||
Maximum drain flow rate |
|
| 240 l/min | ||||
(I) Waste water collector |
| DN 150 mm (6" BSP) | |||||
(3 cm/m (3 %) minimum slope) |
|
| Ø 60 mm (2.36 ") |
| |||
(J) Air vent hole |
|
|
| ||||
(N') Thermic fluid inlet or indirect steam heating |
|
| DN 15 (1/2" BSP) | ||||
(G) Thermic fluid return or indirect steam heating |
|
| DN 15 (1/2" BSP) | ||||
| - Maximum supply pressure |
|
|
| 600 kPa | ||
| - Installed calorifi c power |
|
|
| 47300 kcal | ||
| - Average calorifi c consumption |
|
|
| 13800 kcal/h | ||
| - Inner volume thermic fl uid |
|
|
| 5,33 l | ||
Gas inlet |
|
|
| DN 20 (3/4" BSP) |
|
| |
Combustion products evacuation |
|
|
| Ø 125 mm (5") |
|
| |
(S) Weighing equipment (optional) |
| Ø 4/6 mm |
| ||||
Compressed air inlet (low pressure steam) |
| ||||||
| - Min./max. compress air pressure | 5,5/7 | |||||
| - Consumption |
|
| 10 |
*normal cycle : prewash 3 min at 35 °C, drain. 2 min, main wash 4 min at 65 °C, drain 2 min, rinse 2 min, extract. 2 min, rinse 2 min, ex- tract 2 min, rinse 2 min, extrac. 10 min (cold water supply at 15 °C).
** ECO cycle : normal cycle with rinse 5 l/kg instead of 6 l/kg dry linen.