0108 3 13
Notice Date Page
01201138
INSTRUCTION
HANDBOOK
DOOR LOCK Error 17
Error/Function Cause Action
signal absent from door status
switch, although door is locked.
- Transient fault. No action required.
- Fault in door lock switch or in wiring faulty.
- The PCB is faulty.
- Check if the door is locked.
- Open the door and switch
off power to machine. Wait a
minute or so, switch on power
supply, close door again and try
restarting.
- Check wiring or replace door
lock as appropriate.
- Replace PCB.
START NOT ALLOWED Error 18
The network does not allow start
of the washing programme.
.- Try to reset the error code.
If the error remains, contact
the responsible person for the
network and have the error fi xed.
EMERGENCY STOP Error 15
The emergency stop button has
been pressed.
- Abnormal or dangerous running of the machine. - After the problem which caused
the emergency stop has been
put right, reset the emergency
stop button by turning it until it
pops back out.
- Check wiring.
UNBAL SENSOR FAULT Error 11
- The unbalance safety contact has been activated
for at least 5 seconds during washing before a
distribution.
- The unbalance safety contact fautly or a suspen-
sion spring is broken.
- Bad loading of machine.
- Turn the machine's wall switch
off and check unbalance safety
contact.
- Check suspension.
- Correctly load the drum or put
linen in several nets.
The unbalance safety device has
been activated before spinning.
13. Maintenance
NO INVERTER COMM. Error 13
- Transient fault. No action required.
- Frequency converter faulty.
- Turn the machine's wall
switch off and on again. Start a
program.
- Check the frequency converter.
Communication between PCU
and frequency converter inter-
rupted or disturbed.
LEVEL CALIBRATION Error 14
- If the level system has not been calibrated at the
factory the error message will appear for fi ve
seconds immediately after every program start-up.
The machine can be operated, but the levels will be
slightly wrong, mostly too low.
- Carry out programming anew
and make sure the calibration
values are within the allowed
limits.
The water level system has not
been correctly calibrated.