www.ti.com

SRIO Registers

Table 159. Port Error Detect CSR n (SPn_ERR_DET) Field Descriptions (continued)

Bit

Field

Value

Description

20

RCVD_PKT_NOT_ACCPT

 

Packet-not-accepted control symbol

 

 

0

The port did not receive a packet-not-accepted acknowledge control

 

 

 

symbol.

 

 

1

The port received a packet-not-accepted acknowledge control symbol.

19

PKT_UNEXPECTED_ACKID

 

Unexpected ackID in packet

 

 

0

The port did not receive a packet with unexpected/out-of-sequence

 

 

 

ackID.

 

 

1

The port received a packet with unexpected/out-of-sequence ackID.

18

RCVD_PKT_WITH_BAD_CRC

 

Bad CRC in packet

 

 

0

The port did not receive a packet with a bad CRC value.

 

 

1

The port received a packet with a bad CRC value.

17

RCVD_PKT_OVER_276B

 

Oversize packet

 

 

0

The port did not receive packet that exceeds the maximum allowed

 

 

 

size.

 

 

1

The port received packet that exceeds the maximum allowed size.

16–6

Reserved

0

These read-only bits return 0s when read.

5

NON_OUTSTANDING_ACKID

 

Non-outstanding ackID

 

 

0

The port did not receive a link response with a non-outstanding ackID.

 

 

1

The port received a link response with an ackID that is not outstanding.

 

 

 

The capture registers do not have valid information during this error

 

 

 

detection.

4

PROTOCOL_ERROR

 

Protocol error

 

 

0

The port did not receive an unexpected packet or control symbol.

 

 

1

The port received an unexpected packet or control symbol.

3

Reserved

0

This read-only bit returns 0 when read.

2

DELINEATION_ERROR

 

Delineation error

 

 

0

The port did not detect a delineation error.

 

 

1

The port detected a delineation error. The port received an unaligned

 

 

 

/SC/ or /PD/ or undefined code-group. The capture registers do not

 

 

 

have valid information during this error detection.

1

UNSOLICITED_ACK_CNTL_SYM

 

Unsolicited acknowledge control symbol

 

 

0

The port did not receive an unexpected acknowledge control symbol.

 

 

1

The port received an unexpected acknowledge control symbol.

0

LINK_TIMEOUT

 

Link timeout

 

 

0

The port did not experience a link timeout.

 

 

1

The port experienced a link timeout. The port did not receive an

 

 

 

acknowledge or link-response control symbol within the specified

 

 

 

time-out interval. The capture registers do not have valid information

 

 

 

during this error detection.

220

Serial RapidIO (SRIO)

SPRUE13A –September 2006

Submit Documentation Feedback

Page 220
Image 220
Texas Instruments TMS320TCI648x Rcvdpktnotaccpt, Pktunexpectedackid, Rcvdpktwithbadcrc, RCVDPKTOVER276B, Protocolerror