Texas Instruments TMS320TCI648x manual Port Error Detect CSR n SPnERRDET

Models: TMS320TCI648x

1 256
Download 256 pages 4.34 Kb
Page 219
Image 219

www.ti.com

SRIO Registers

5.82 Port Error Detect CSR n (SPn_ERR_DET)

Each of the four ports is supported by a register of this type (see Table 158). The port error detect CSR n (SPn_ERR_DET) is shown in Figure 145 and described in Table 159.

Table 158. SPn_ERR_DET Registers and the Associated Ports

Register

Address Offset

Associated Port

SP0_ERR_DET

2040h

Port 0

SP1_ERR_DET

2080h

Port 1

SP2_ERR_DET

20C0h

Port 2

SP3_ERR_DET

2100h

Port 3

 

 

 

 

Figure 145. Port Error Detect CSR n (SPn_ERR_DET)

 

31

30

 

 

 

 

 

 

 

 

 

 

 

 

24

ERR_IMP_

 

 

 

 

 

 

 

 

Reserved

 

 

 

 

SPECIFIC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/W-0

 

 

 

 

 

 

 

 

 

R-0

 

 

 

 

23

22

 

 

21

 

 

20

 

 

19

18

 

17

16

 

CORRUPT_

CNTL_SYM_

 

RCVD_PKT_

 

PKT_

RCVD_PKT_

RCVD_PKT_

 

Reserved

UNEXPECTED_

UNEXPECTED_ WITH_BAD

 

Reserved

CNTL_SYM

NOT_ACCPT

 

OVER_276B

 

 

ACKID

 

 

 

ACKID

_CRC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R-0

R/W-0

 

 

R/W-0

 

 

R/W-0

 

 

R/W-0

R/W-0

 

R/W-0

R-0

15

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

R-0

 

 

 

 

 

7

6

 

5

 

 

 

4

 

3

 

2

 

1

0

 

 

NON_

 

PROTOCOL_

 

 

DELINEATION_

UNSOLICITED_

LINK_

Reserved

OUTSTANDING_

Reserved

 

ERROR

 

ERROR

ACK_CNTL_SYM

TIMEOUT

 

 

ACKID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R-0

 

R/W-0

 

 

 

R/W-0

 

R-0

 

R-00h

 

R/W-0

R/W-0

LEGEND: R/W = Read/Write; R = Read only; -n= Value after reset

 

 

 

 

 

 

Table 159. Port Error Detect CSR n (SPn_ERR_DET) Field Descriptions

Bit

Field

Value

Description

31

ERR_IMP_SPECIFIC

 

Implementation-specific error. This bit covers errors that are a result of

 

 

 

an illegal field in a maintenance packet, an illegal destination ID, and

 

 

 

an unsupported transaction.

 

 

0

An implementation specific error has not been detected.

 

 

1

An implementation specific error has been detected.

30–23

Reserved

0

These read-only bits return 0s when read.

22

CORRUPT_CNTL_SYM

 

Bad CRC in control symbol

 

 

0

The port did not receive a control symbol with a bad CRC value.

 

 

1

The port received a control symbol with a bad CRC value.

21

CNTL_SYM_UNEXPECTED_ACKID

 

Unexpected ackID in control symbol

 

 

0

The port did not receive an acknowledge control symbol with an

 

 

 

unexpected ackID (packet-accepted or packet-retry).

 

 

1

The port received an acknowledge control symbol with an unexpected

 

 

 

ackID (packet-accepted or packet-retry). The capture registers do not

 

 

 

have valid information during this error detection.

SPRUE13A –September 2006