01201138

0310

1

15

 

INSTRUCTION

 

 

 

15. Electric diagrams

Notice

Date

Page

HANDBOOK

 

 

 

 

 

 

Configuration of variator KEB type 5

list of CP parameters

Code

Function

CP. 0

Password input

CP. 1

Inverter status display

CP. 2

Utilization

CP. 3

Actual frequency display

CP. 4

Peak of load

CP. 5

Variator temperature

CP. 6

Apparent current

CP. 7

Active set

CP. 8

Transmission speed

CP. 9

Last error

CP.10

Overcurrent

CP.11

Overload

CP.12

Overvoltage

CP.13

Overtemperature

CP.14

Max. constant current set 0

CP.15

Max. ramp current set 0

CP.16

Boost stop set 0

CP.17

Max. constant current wash set 1

CP.18

Max. ramp current wash set 1

CP.19

Regulator of proportional speed wash set 1

CP.20

Regulator of integral speed wash set 1

CP.21

Boost wash set 1

CP.22

Autoboost wash set 1

CP.23

Max. constant current distribution set 2

CP.24

Max. ramp current distribution set 2

CP.25

Regulator of proportional speed distribution set 2

CP.26

Regulator of integral speed distribution set 2

CP.27

Boost distribution set 2

CP.28

Autoboost distribution set 2

CP.29

Max. constant current extraction set 3

CP.30

Max. ramp current extraction set 3

CP.31

Overmodulation extraction set 3

CP.32

Max. constant current positionning set 4

CP.33

Max. ramp current positionning set 4

CP.34

Boost positionning set 4

CP.35

Autoboost positionning set 4

NOTA :

After parameterizing it is compulsory to barr the unit against access. Enter the value 100 in CP.0 after loading the programme in the inverter.

In after sales you can enable the access to CP parameters by entering the value 200 in CP.O

Page 164