9. Installation
INSTRUCTION
HANDBOOK
Steam connection
For transport reasons, the steam electrovalve is dismantled and placed in the cardboard box supplies.
The inlet pipe to the machine has to be fi t with a manual stopping valve to ease installation and maintenance.
Connect the steam electrovalve on its pipe union.
Assemble the set (P.G.F.V.U) between the machine and steam piping.
Hereunder values apply to the steam pressure :
Recommended pressure : 300 at 600 kPa (3 at 6 kg/cm²) (43.5 at 87 psi)
Limiting of values :
mini. 100 kPa (1 kg/cm²) (14.5 psi) maxi. 600 kPa (6 kg/cm²) (87psi)
Connection size : DN 20 (¾" BSP).
Connect the steam installation on the top of the machine (see example sketch).
A
SSteam inlet
YManual stop wheel valve DN 20 (¾" BSP) (provided by customer)
PSteam special fl exible pipeDN 20 (¾" BSP)(provided)
GNipple DN 20 (¾" BSP) (provided by customer)
FSteam fi lter DN 20 (¾" BSP) (provided)
VSteam electrovalve DN 20 (¾" BSP) (provided)
D1680
Steam set
UPipe union DN 20 (¾" BSP) (provided)
MIsulating (provided)
D1679