Hach 900 manual Appendix C Exploded View 3, Number

Page 49

Appendix C

Exploded View (3 of 6)

 

29

 

 

 

 

 

 

 

28

 

 

 

 

 

 

 

26-27

 

 

 

1

 

 

 

25

 

 

 

 

2

 

24

 

 

 

 

 

 

 

 

 

 

 

23

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

21

 

 

 

 

 

3

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

19

 

 

 

 

 

 

5-6

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

15-16

 

 

 

 

 

 

 

14

 

 

 

 

 

7

 

 

 

 

 

 

 

 

12-13

 

 

 

9

8

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

Item

Description

QTY

Part

Item

Description

QTY

Part

Number

Number

Number

Number

 

 

 

 

1

900 Controller Case

1

8619

16

O-ring Lubricant

1

SE 1048

2

Hex Nut

4

SE 701

17

Mounting Plate

1

2547

3

Screw/Threadlock (SE 957)

2

SE 747

18

Auxiliary Cable Assembly

1

8913

4

PCB Assembly

1

8538

19

Connector Cap

1

2859

5

Screw

2

SE 747

20

Screw

12

SE 229

6

Threadlock

2

SE 957

21

Slow Blow Fuse, 5A, 250 V

1

8753

7

Ultrasonic Sensor Gasket

1

8609

22

O-ring

1

3321

8

Retainer Plate

1

2548

23

Fuse Holder, 5 x 20 mm

1

3320

9

Retainer Plate Gasket

1

2550

24

O-ring

1

3319

10

Hex Nut

1

SE 701

25

Fuse Mounting Plate

1

8540

11

Humidity Indicator Overlay

1

4319

26

Mounting Plate Gasket

1

2556

12

Retainer Plate

1

2554

27

O-ring Lubricant

1

SE 1048

13

O-ring Lubricant

1

SE 1048

28

Mounting Plate

1

2555

14

Retainer Plate Gasket

1

2557

29

Fuse Holder Cable Assy.

1

3146

15

Mounting Plate

1

2549

 

 

 

 

 

Page 49

8544apdx_engdraw.fm

Exploded View Drawings

Image 49
Contents Sigma 900 Composite Sampler Page Table of Contents Table of Contents Pump/Controller Housing Controller DimensionsSample Volume Sample Volume RepeatabilityPage Instrument Description Interface ConnectorsReceptacle Caps General InformationSection Humidity IndicatorFront Panel Keypad and DisplaySafety Information Safety InformationUse of Hazard Information Precautionary LabelsHazardous Locations Peligro Confined Space EntryDefinition of Confined Space Installation Selecting the Installation SiteUnpacking the Instrument Attaching the Intake Line Mounting the SamplerVinyl Intake Tubing Teflon-Lined Polyethylene Intake LineInstalling the Full Bottle Shut-Off Setting Up the Intake Line and StrainerSetting Up the Intake Line and Strainer Choosing BottlesPower Connections Power Connections12 V dc 12 V dc Connector Pin AssignmentsAuxiliary Connection Auxiliary Pin AssignmentsMA Input Contact ClosuresAuxiliary Connection Splitter Interface 20 mA Interface and Pulse Duration InputPage Keypad and Key Functions Tips and Techniques for Programming the Instrument Tips and Techniques for Programming the InstrumentBottle Setup Mode Section Setting the Time and DateSetting the Time and Date 1035 AM 24OCT00Section Explanations of Program Messages Data Logging Manual ModeManually Operating the Sample Pump Mode Measurements Triggered by Liquid Levels or FlowMeasurements Triggered by Liquid Levels or Flow Other Displayed Messages Section Programming the Sampler for Level ControlSection Flow Proportional Operation How to Calculate Pulses/CountsExample Flow Proportional OperationTherefore, the value for Intv = Cnts is Calculate t You want to collect 32 samples over an 8-hour period Page Removing and Opening the Controller Cleaning the SamplerRe-installing the Bottom Panel Re-installing the Bottom PanelCircuit Board Identification Section Internal Desiccant ModuleInternal Desiccant Module Memory Battery Internal Case Humidity IndicatorMotor/Gear Box Motor/Gear BoxOrdering Information for the U.S.A Repair ServiceContact Information for Europe Limitations Limited WarrantyLimitation of Remedies Page Description Part Number Parts and AccessoriesTray/Positioner Page Program Flow Chart Page Temperature MaintenanceLead-Acid Gel Cell Batteries ChargingNickel-Cadmium Battery Storage Recommendations Lead-Acid Battery Storage RecommendationsStorage Temperature Maximum Recommended Storage Time Appendix BItem Number Description Exploded View 1Exploded View Drawings Appendix C Exploded View 2 Appendix C Exploded View 3 Part Description Appendix C Exploded View 4Part Appendix C Exploded View 5 Item Number Description Part Number Appendix C Exploded View 6