Click Viewer Setup for configuring the Smart Viewer related settings. This Viewer Setup consists of 5 different items: Video Recording, File Converting, Sequence Time, OSD Display, and Auto Connection.

1

2

34

56

78

1.The currently displayed video data can be saved in a DVR format (*.dvr) file. The related settings are made here.

2.A DVR file can be converted into a JPEG or AVI file. The destination folders are determined here.

3.You can set the sequence time (or screen change time) interval for the auto sequence mode.

4.The OSD display on Smart Viewer can be decided here.

5.You can decide whether Smart Viewer automatically connects to the designated DVR or site when it starts running.

6.You can enable/disable alarming and set the alarming duration.

7.You can set the port for callback connection.

8.You can set the language for display.

Video Recording

-Naming convention

When recording the currently displayed video data into DVR files, you can assign the file naming rule to DRV files.

- Location

5162/5082

- Recording Time

You can set the maximum recording time when saving the video data. You can set the time ranging from 1 to 10 minutes. If the recording time exceeds the preset value, the program stops recording.

File Converting

5162/5082

You can convert a DVR file saved on your PC into JPEG or AVI. The default destination folder for file conversion is < Smart Viewer directory>\ frame.” You can change it on your own.

Sequence Time

In monitoring mode, when the screen change (auto sequence) mode is active, the camera channels change at an interval of this time. You can set the time ranging from 5 to 30 seconds.

OSD Display

You can set if OSD shall be displayed on each channel of Smart Viewer. However, the icons for audio, PTZ, recording, and alarm/motion event are normally displayed regardless of this setting.

Callback Connection

Set the port for callback connection.

Auto Connection

You can set if Smart Viewer is automatically connected to the selected DVR or site when starting the program. If you check Auto Connection Enable, available DVRs and sites are displayed in the pull-down list. After selecting one from the list, Smart Viewer connects to the selected DVR or site whenever it is started.

10 Smart Viewer

Smart Viewer _53

Image 57
Contents Real Time DVR WHAT’S Included with Your DVR Key features of your DVRSafety regulations Operating Temperature BatteryBefore start Standards ApprovalsContents Search and Play Controls on the DVR Introducing your real time DVRFast/Step Rewind Button Power LEDStop Button PLAY/PAUSE ButtonRear Rear Panel JacksUsing the Numeric Buttons Remote ControlChanging the Remote Control ID Installation Checking Installation EnvironmentHDD Addition Setting the jumper Things to consider when adding a hard diskHow to add hard disks SlaveScrewdriver Bracket Hddb HddaBRACKET-HDDB Connecting VIDEO, AUDIO, and Monitor Connecting the Network Connecting with other devicesConnecting to Internet through Ethernet 10/100BaseT Illustrations are described based on SHR-5162Connecting the Alarm INPUT/OUTPUT Connecting the USBConnecting to Internet through Adsl  5082 Alarm IN/OUT Ports  5162 Alarm IN/OUT PortsConnecting the RS-485 Device Live Live Screen ModeOperating the System Live screen iconsLive screen modes Selecting live screen mode Setting Audio ON/OFFAudio On/Off setting in full screen mode Audio On/Off setting in 16-split modeEvent Monitoring Freezing and ZoomingFreeze function Zoom functionSPOT-OUT Monitoring Fan Information Error occurs in the fan Refer to the manualDate/Time/Language Setup Menu setupBefore USE SystemPassword System Log Load Factory DefaultEvent Log System LogStorage Setup System Information and SetupRemote Control Device Export/Import the ConfigurationCamera Camera ConfigurationScreen Setup MonitoringPTZ Device Record Quality & Auto Deletion Record ModeEvent Record Duration Record Rate & Video SizeEvent Record Mode Alarm Detection SetupMotion Detection Setup Video Loss Detection Setup ScheduleRecord Schedule Alarm Out Schedule IP SettingsNetwork Transfer Protocol Settings Transfer Picture Settings Callback SettingsYou can configure the video size and quality for Transferring picturesPort configuration for connecting Smart Viewer Configuring Network Poor image problem in Smart Viewer Case of TCP transfer protocolTo configure the related settings BackupPTZ Camera Control Mode PTZ camera controlBasic PTZ Operations Preset Setup Camera Menu SetupTo set a preset Other View Preset ViewSamsung PanRecording REC Normal RecordingRecord Schedule Calendar Search Search and playEvent Search To perform a calendar searchGO to First Search Date Time SearchTo perform an event search To perform a date/time searchGO to Last Search Backup SearchPlayback Go to Last Speed play  Playback mode Viewing still images  Audio playbackPC Specification Recommended Main FeaturesSmart Viewer IntroductionExecution Setup Mode This button is used for connecting to CallbackThis screen shows the monitoring sites  Setup Item Selection buttons DVR Setup Save/Cancellation of Revised Information  Closing the setup windowUser Password For more details, see , Menu Setup Admin Password Camera Camera Configuration Only English is available for the title Retype it  Recording  Monitoring Setup Schedule Network Password  For the network password, you can Network Viewer Setup Site Setup You can set the language to be displayed on Smart Viewer DVR List If you really want to modify the DVR, disconnect Smart Viewer, the following message appearsDVR and retry to modify it  Site ListVersion To edit the DVR, go to the DVR listTo add a DVR to the site, select a DVR and click Add Password certification failure Smart Viewer Monitoring ModeConnection Failure Cases Upgrading the DVR softwareConnection Screen Mode Conversion ButtonTime Information Connection Information Time Change When the date and time of the DVR are changed Event Log Display WindowClick Log to activate the log display window  Black When Smart Viewer cannot be connected to a DVR Sequence Mode ButtonCamera Connection Indication Window Screen Split Selection ButtonsCallback Button Next ButtonFavorite Button Video Recording ButtonAudio Volume Control Button Video Brightness/Contrast Control ButtonPTZ Camera Control Buttons  The other cameras do not support those functions Self Menu Setup of PTZ deviceSearch Mode Audio Volume, Video Brightness/ Contrast Buttons Remote ModeVideo Save Backup/Video Conversion/Print/Setup Calendar WindowViewer Setup File Converting AVI Location Print button Viewer Setup File Converting Jpeg LocationSetup Mode button File Conversion buttonLocal Mode Time LineReload button Appendix Product SpecificationVideo MPEG4 True Recording ips 0.938/1.875/3.75/7.5/15/30ipsTrue Recording ips 0.781/1.563/3.125/6.25/12.5/25i Triplex 16 split  15 Channel Live +1Channel PB  5082 Outline Drawings Outline Drawings 5162 Outline Drawings Classification Detailed Items Factory Setup Factory DefaultCH1 DNS Troubleshooting FAQ  If you forget the password, you shall reset the DVR to If all your efforts as above end up with nothing, check Works for the shop where you bought the product DVR has problem. DVR will not work in order to protect When you use DHCP/ADSLPPPoE for connection  Check if 3 Smart Viewer users are in connection with Make sure that the external storage device installed is  Make sure that the additional external HDD installedPreamble Open Source License Report on the ProductAppendix No Warranty Repair or Correction How to Apply These Terms to Your New ProgramsWe protect your rights with a two-step method You must cause the whole of the work to Appendix Executable How to Apply These Terms to Your New Libraries FoundationLicense, or at your option any later version Loss of USE, DATA, or Profits or Business Interruption OpenSSL LicenseThis Software is Provided by Eric Young ‘‘AS IS’’