Samsung AR07JSFPEWQNEU General information, Installing the unit, English-27, T05s In llan atio

Page 27

Safety precautions

Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.

Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components.

Verify that installation and testing operations are performed by qualified personnel.

Verify that the air conditioner is not installed in an easily accessible area.

General information

Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation.

For maximum safety, installers should always carefully read the following warnings.

Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred.

This manual explains how to install an indoor unit with a split system with two SAMSUNG units.

The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.

The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the“Operating limits”table, included in the manual, shall immediately invalidate the warranty.

The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.

Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.

In order to help prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.

Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations should be performed by qualified personnel only.

The unit contains moving parts, which should always be kept out of the reach of children.

Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may cause electric shocks or fires.

Do not place containers with liquids or other objects on the unit.

All the materials used for the manufacture and packaging of the air conditioner are recyclable.

The packing material and exhaust batteries of the remote controller(optional) must be disposed of in accordance with current laws.

The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.

Installing the unit

IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes.

Upon receipt, inspect the product to verify that it has not been damaged during transport.

If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer.)

t05s In llan atio

English-27

Maldives ET IB&IM_DB68-06219A-00_EN.indd 27

2016/5/16 10:26:44

Image 27 Contents
Air conditioner Features of your new air conditioner Contents English-4 Safety precautions01epaPr n atio English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningEnglish-10 Checking before useOperation ranges Model AJEnglish-11 Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsEnglish-12 Inserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Basic fun n iot Button to adjust the temperaturePress English-15Horizontal air flow Adjusting the air flow directionPress the Air swing button on the remote controller Vertical air flow24C~30C Using the Smart Saver functionUsing the turbo function English-17English-18 Using the Quiet functionUsing the Auto Clean function When the air conditioner is turned onWhen the air conditioner is on and in cool/heat mode ModeEnglish-19 English-20 Setting the On/Off timerPress the On Timer/Off Timer button Additional options available in On timer modeTurn off automatically From the moment you have set the timerEnglish-21 If the air conditioner is on If the air conditioner is offCleaning the air conditioner Cleaning the air filter Removing the Air filterEnglish-23 English-24 Maintaining the air conditionerEnglish-25 TroubleshootingAdjustment is not Conditioner doesWhen an indoor unit indicator blinks, contact the nearest These modes, desired temperature is set to auto and youCheck if you press the Set button on the remote controller Room or operate the air conditioner in Fan mode forT05s In llan atio Installing the unitGeneral information English-27Indoor unit Choosing the installation locationPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyModel Where sulfide gas existsOutdoor Unit English-29English-30 When installing 1 outdoor unitWhen installing more than 1 outdoor unit Space Requirements for Outdoor UnitUnit mm AccessoriesAccessories in the indoor unit case English-31Tools for test operations Accessories in the outdoor unit caseOptional accessories Tools required for installation General ToolsIf you fix the indoor unit on a window frame Fixing the installation plateEnglish-33 Fix the indoor unit If you fix the indoor unit on a wallEnglish-34 Connecting the assembly cableCable specification Connecting the cableEach wire is labeled with the corresponding terminal number InStAllAtIOnEnglish-35 Torque English-36Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Evacuating the indoor unitCutting or extending the pipe English-37English-38 Put a flare nut slightly into the pipe and modify the flareDepth a Be bent Drain hose installationEnglish-39 Wall Indoor unit Drain hose Drain hose must notCheck for leakage on both side of the drain outlet English-40Drain hole Drain plug Evacuating the connected pipesEnglish-41 Connect a drain hose to the drain plugIf you use a pipe longer than 5 m Adding RefrigerantEnglish-42 Outer TorqueEnglish-43 English-44 Performing the gas leak testsEnglish-45 Outdoor unit installed on the wall by rackFixing the indoor unit in place Fixing the outdoor unit in placePump down procedure when removing the product Final check and trial operationEnglish-46 English-47 How to connect your extended power cablesOnly for multi system Sub PCB installationoptionalWried remote controller, central remote controller etc English-48English-49 Questions or COMMENTS? Country
Related manuals
Manual 28 pages 39.02 Kb Manual 50 pages 48.99 Kb Manual 1 pages 46.73 Kb Manual 51 pages 18.39 Kb Manual 28 pages 11.1 Kb Manual 28 pages 7.21 Kb Manual 28 pages 12.32 Kb Manual 28 pages 13.27 Kb Manual 28 pages 21.38 Kb Manual 28 pages 20.36 Kb Manual 28 pages 35.95 Kb Manual 49 pages 54.48 Kb Manual 29 pages 21.43 Kb