Samsung AR09JSFPEWQNZE, AR12JSFPEWQNET, AR09JSFPEWQNET manual Safety precautions, English-4

Page 4

Safety precautions

Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance.

Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com.

Important safety symbols and precautions:

WARNING

Hazards or unsafe practices that may result in severe

personal injury or death.

 

CAUTION

Hazards or unsafe practices that may result in minor

personal injury or property damage.

 

 

Follow directions.

 

 

Cut-off the power supply.

 

Do NOT attempt.

 

 

Do NOT disassemble.

 

Make sure the machine is grounded to prevent electric shock.

FOR INSTALLATION

 

 

WARNING

 

Use the power line with the power specifications of the product or higher and use the power line for this appliance only. In addition, do not use an extension line.

Extending the power line may result in electric shock or fire.

Do not use an electric transformer. It may result in electric shock or fire.

If the voltage/frequency/rated current condition is different, it may cause fire.

The installation of this appliance must be performed by a qualified technician or service company.

Failing to do so may result in electric shock, fire, explosion, problems with the product, or injury and may also void warranty on the installed product.

Install a Isolation Switch next to the Air Conditioner (but not on the panels of the Air Conditioner)and circuit breaker dedicated to the air conditioner.

Failing to do so may result in electric shock or fire.

Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.

Failing to do so may result in electric shock, fire, explosion, problems with the product.

English-4

Maldives ET IB&IM_DB68-06219A-00_EN.indd 4

2016/5/16 10:26:35

Image 4 Contents
Air conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epaPr n atioFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Checking before use Operation rangesModel AJ English-10Checking the name of the parts Main partsDisplay English-11Remote controller buttons Checking the remote controllerEnglish-12 Remote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function Button to adjust the temperature PressEnglish-15 Basic fun n iotAdjusting the air flow direction Press the Air swing button on the remote controllerVertical air flow Horizontal air flowUsing the Smart Saver function Using the turbo functionEnglish-17 24C~30CUsing the Quiet function Using the Auto Clean functionWhen the air conditioner is turned on English-18Mode When the air conditioner is on and in cool/heat modeEnglish-19 Setting the On/Off timer Press the On Timer/Off Timer buttonAdditional options available in On timer mode English-20From the moment you have set the timer English-21If the air conditioner is on If the air conditioner is off Turn off automaticallyCleaning the air conditioner Removing the Air filter Cleaning the air filterEnglish-23 Maintaining the air conditioner English-24Troubleshooting Adjustment is notConditioner does English-25These modes, desired temperature is set to auto and you Check if you press the Set button on the remote controllerRoom or operate the air conditioner in Fan mode for When an indoor unit indicator blinks, contact the nearestInstalling the unit General informationEnglish-27 T05s In llan atioChoosing the installation location Power supply line, fuse or circuit breaker a place where the air filter can be replaced easily Indoor unitWhere sulfide gas exists Outdoor UnitEnglish-29 ModelWhen installing 1 outdoor unit When installing more than 1 outdoor unitSpace Requirements for Outdoor Unit English-30Accessories Accessories in the indoor unit caseEnglish-31 Unit mmAccessories in the outdoor unit case Optional accessoriesTools required for installation General Tools Tools for test operationsFixing the installation plate English-33Fix the indoor unit If you fix the indoor unit on a wall If you fix the indoor unit on a window frameConnecting the assembly cable Cable specificationConnecting the cable English-34InStAllAtIOn Each wire is labeled with the corresponding terminal numberEnglish-35 English-36 Smooth the cut edgesCut off the remaining foam insulation TorqueEvacuating the indoor unit Cutting or extending the pipeEnglish-37 Unscrew the caps at the end of each pipePut a flare nut slightly into the pipe and modify the flare English-38Depth a Drain hose installation English-39Wall Indoor unit Drain hose Drain hose must not Be bentEnglish-40 Check for leakage on both side of the drain outletEvacuating the connected pipes English-41Connect a drain hose to the drain plug Drain hole Drain plugAdding Refrigerant English-42Outer Torque If you use a pipe longer than 5 mEnglish-43 Performing the gas leak tests English-44Outdoor unit installed on the wall by rack Fixing the indoor unit in placeFixing the outdoor unit in place English-45Final check and trial operation Pump down procedure when removing the productEnglish-46 How to connect your extended power cables English-47Sub PCB installationoptional Wried remote controller, central remote controller etcEnglish-48 Only for multi systemEnglish-49 Questions or COMMENTS? Country
Related manuals
Manual 28 pages 39.02 Kb Manual 50 pages 48.99 Kb Manual 1 pages 46.73 Kb Manual 51 pages 18.39 Kb Manual 28 pages 11.1 Kb Manual 28 pages 7.21 Kb Manual 28 pages 12.32 Kb Manual 28 pages 13.27 Kb Manual 28 pages 21.38 Kb Manual 28 pages 20.36 Kb Manual 28 pages 35.95 Kb Manual 49 pages 54.48 Kb Manual 29 pages 21.43 Kb