Samsung AR24JRFSBWKNMG manual Fixing the installation plate, Optional accessories, English-37

Page 37

• The flare nuts are attached to the end of each pipe of an evaporator or a service port.

Use the nuts when connecting the pipes.

The wire assembly cable is optional. If it is not supplied, use the standard cable.

The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below.

Optional accessories

The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner.

Insulated Assembly Pipe,

Insulated Assembly Pipe,

Insulated Assembly Pipe,

PE T3 Foam Tube

Vinyl Tapes (2)

Drain Hose,

Ø6.35 mm x 5 m (1) ✴✴12/18✴✴

Ø12.70 mm x 5 m (1)

Ø15.88 mm x 5 m (1) ✴✴24JFC✴✴

Insulation (1)

length 2 m (1)

Ø6.35 mm x 4 m (1) ✴✴24✴✴

✴✴12/18✴✴

Ø15.88 mm x 4 m (1) ✴✴24JFB✴✴

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07stIn llan atio

Putty 100 g (1)

Pipe Clamps A (3)

Pipe Clamps B (3)

Cement Nails (6)

M4 x 25 Tapped

Screws (6)

 

 

 

 

4-wire

Assembly Cable (1) ✴✴12/18/24✴✴

• If these accessories are supplied, they will be in the accessory box.

Tools required for installation

General Tools

• Vacuum Pump(Backward flowing prevention)

• Manifold Gauge

• Stud Finder

• Torque Wrench

• Pipe Cutter

• Reamer

• Pipe Bender

• Spirit Level

• Screw Driver

• Spanner

• Drill

• L Wrench

• Measuring Tape

Tools for test operations

 

 

 

• Thermometer

• Resistance Meter

 

• Electroscope

 

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

• Right (A)

Direction of pipe

 

 

 

• Left (B)

 

 

• Underside_right (C)

A

B

• Rear_right or left (D)

D

D

 

C

 

You can install the refrigerant pipe in the left/right/bottom, or the rear side of the indoor unit.

• If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.

English-37

MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-05188A-00_UX.indd 37

2/17/2015 2:14:04 PM

Image 37
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningOperation ranges Checking before useEnglish-10 English-11 Technical SpecificationsAR24JRFNCWK/MG English-12Main parts Checking the name of the partsDisplay English-13Remote controller buttons Checking the remote controllerEnglish-14 Low Battery warning Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-17 Vertical air flow Adjusting the air flow directionHorizontal air flow English-18Setting the On timer Setting the On/Off timerYou can adjust the fan speed in Cool/Fan/Heat ARJQ mode English-19English-20 Setting the Off timerButton Mode Additional options available in modeEnglish-21 English-22 Step cooling functionUsing the Comfort function Using the Fast functionEnglish-23 Press the Options buttonEnglish-24 Using the Single User functionPress the Single user button Setting the Beep sound Using the Auto Clean functionEnglish-25 Cleaning the indoor unit Cleaning the air conditionerSuch as thinner, kerosene and acetone etc. to clean Cleaning the outdoor unit heat exchangerRemoving the Air filter Cleaning the air filterEnglish-27 Remove the air filter from the main bodyEnglish-28 Reassembling the Air filterTop of the Air filter into the main body.. ➀ English-29 Maintaining the air conditionerAir conditioner TroubleshootingEnglish-30 Take the cover off and takeCheck the Drains have been cleared Regular Maintenance Button or disconnect the power plug/switchError is indicated Heard when refrigerant flow movement changes. It is normalEnglish-32 General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit Where sulfide gas existsEnglish-34 English-35 When installing more than 1 outdoor unitTop view Side view Accessories in the indoor unit case AccessoriesAccessories in the outdoor unit case English-36Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsEnglish-38 Assembling the hanger screwRemoving the screws This QR code for detail video of indoor unit installationRemoving the Cover panel Before mounting the indoor unit English-39English-40 Assembling the Cover panel After mounting the indoor unitCable specification Connecting the assembly cableConnecting the cable English-41Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryEnglish-42 Smooth the cut edges English-43Cut off the remaining foam insulation TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-44 English-45 English-46 Drain hose installationEnglish-47 Changing direction of the drain hoseCheck for leakage on both side of the drain outlet English-48 Evacuating the connected pipesConnect a drain hose to the drain plug Drain hole Drain plugEnglish-49 Adding RefrigerantIf you use a pipe longer than 4 m24JFB or If you use a pipe shorter than 4 m24JFB orCylinder with siphon English-50English-51 Performing the gas leak testsOuter Tightening torque 07stIn llan atio To check for gas leaks on the outdoor unitFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-52 English-53 Smart Install modeOff / Blinking / On English-54English-55 Final check and trial operationEnglish-56 Packing and unpacking guideEnglish-57 How to connect your extended power cablesAtio 021-8255 CE English-60

AR24JRFNBWKNMG, AR24JRFSBWKNMG specifications

Samsung is renowned for its innovation and quality in the electronics industry, and the AR24JRFSBWKNMG and AR24JRFNBWKNMG air conditioners exemplify this commitment. Designed for efficiency and comfort, these models are ideal for residential and commercial spaces, providing optimal climate control.

One of the standout features of both models is the inverter technology. This technology allows the air conditioners to adjust their cooling output based on the temperature of the room, ensuring energy efficiency and consistent comfort. By running the compressor at varying speeds, these units minimize energy consumption while maintaining the desired indoor environment.

The AR24JRFSBWKNMG and AR24JRFNBWKNMG also incorporate a robust air filtration system. Equipped with a multi-stage filter, these units effectively capture dust, allergens, and other airborne particles, improving indoor air quality. This is particularly beneficial for allergy sufferers or those living in urban areas with high levels of pollution.

Noise levels are another critical consideration for any air conditioning system. Both models operate quietly, thanks to their advanced design and technology. The noise reduction features ensure that the air conditioners can function without disrupting your peace, making them suitable for bedrooms, living rooms, and office spaces.

Additionally, Samsung has prioritized user convenience with smart features. The air conditioners can be controlled remotely via a smartphone app, allowing users to adjust settings from anywhere. This smart capability ensures that your space is at the perfect temperature upon arrival, maximizing comfort and ease.

Energy efficiency is further complemented by the inclusion of a high-efficiency compressor, which contributes to lower electricity bills. The models have received a high Energy Efficiency Ratio (EER) rating, making them not only eco-friendly but also cost-effective.

Moreover, both air conditioners come with a sleek and modern design, seamlessly blending into a variety of interior styles. The compact size is ideal for space-saving installations, enhancing the aesthetic appeal of any room.

In summary, the Samsung AR24JRFSBWKNMG and AR24JRFNBWKNMG air conditioners provide a combination of advanced technology, energy efficiency, and aesthetic design. With features such as inverter technology, smart controls, and exceptional air filtration, these units cater to the needs of modern consumers seeking comfort and reliability in their climate control solutions.