Samsung AR24JRFSBWKNMG English-43, Smooth the cut edges, Cut off the remaining foam insulation

Page 43

Installing and connecting the assembly pipe of the indoor unit

Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used.

There are 2 refrigerant pipes of different diameters:

 

07stIn

 

 

• The smaller one is for the liquid refrigerant

 

lla

• The larger one is for the gas refrigerant

 

 

n

A short pipe is already fitted to the air conditioner. You may

 

atio

 

 

need to extend the pipe using the assembly pipe (optional).

 

 

The connection procedure for the refrigerant pipe varies

 

 

according to the exit position of the pipe when facing the wall:

 

 

• Right(A)

A

B

• Left(B)

 

C

• Underside(C)

 

 

 

• Rear

 

 

1.Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit unless you connect the pipe directly from the rear.

2.Smooth the cut edges.

3.Remove the protection caps of the pipes and connect the assembly

pipe to each pipe. Tighten the nuts first with your hands, and then with a torque wrench, applying the following torque:

• If you want to shorten or extend the pipes, refer to page 44~45.

4.Cut off the remaining foam insulation.

5.If necessary, bend the pipe to fit along the bottom of the indoor unit. Then pull it out through the appropriate hole.

The pipe should not project from the rear of the indoor unit.

The bending radius should be 100 mm or more.

Outer Diameter

Torque

 

 

N•m

kgf•cm

 

 

 

 

ø6.35 mm

14~18

140~180

 

 

 

ø9.52 mm

34~42

350~430

 

 

 

ø12.70 mm

49~61

500~620

 

 

 

ø15.88 mm

68~82

690~830

 

 

 

6.Pass the pipe through the hole in the wall.

7.For further details on how to connect to the outdoor unit and evacuate the air, refer to page 48~50.

• The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test;

refer to page 52 for further details.

• Tighten the flare nut with torque wrench according to specified method.

If the flare nut is over-tightened, the flare may break and cause refrigerant gas leakage.

DO NOT WALL UP THE PIPE CONNECTION !

All refrigerant pipe connection must be easy accessible and serviceable.

English-43

MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-05188A-00_UX.indd 43

2/17/2015 2:14:14 PM

Image 43
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningOperation ranges Checking before useEnglish-10 English-11 Technical SpecificationsAR24JRFNCWK/MG English-12English-13 Checking the name of the partsMain parts DisplayRemote controller buttons Checking the remote controllerEnglish-14 Inserting the batteries Remote controller displayLow Battery warning Storing the remote controllerBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-17 English-18 Adjusting the air flow directionVertical air flow Horizontal air flowEnglish-19 Setting the On/Off timerSetting the On timer You can adjust the fan speed in Cool/Fan/Heat ARJQ modeEnglish-20 Setting the Off timerButton Mode Additional options available in modeEnglish-21 English-22 Step cooling functionPress the Options button Using the Fast functionUsing the Comfort function English-23English-24 Using the Single User functionPress the Single user button Setting the Beep sound Using the Auto Clean functionEnglish-25 Cleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit Such as thinner, kerosene and acetone etc. to cleanRemove the air filter from the main body Cleaning the air filterRemoving the Air filter English-27English-28 Reassembling the Air filterTop of the Air filter into the main body.. ➀ English-29 Maintaining the air conditionerTake the cover off and take TroubleshootingAir conditioner English-30Heard when refrigerant flow movement changes. It is normal Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Error is indicatedEnglish-32 General informationIndoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerOutdoor Unit Where sulfide gas existsEnglish-34 English-35 When installing more than 1 outdoor unitTop view Side view English-36 AccessoriesAccessories in the indoor unit case Accessories in the outdoor unit caseTools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsEnglish-38 Assembling the hanger screwEnglish-39 This QR code for detail video of indoor unit installationRemoving the screws Removing the Cover panel Before mounting the indoor unitEnglish-40 Assembling the Cover panel After mounting the indoor unitEnglish-41 Connecting the assembly cableCable specification Connecting the cableEach wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryEnglish-42 Torque English-43Smooth the cut edges Cut off the remaining foam insulationCutting or extending the pipe Evacuating the indoor unitEnglish-44 English-45 English-46 Drain hose installationEnglish-47 Changing direction of the drain hoseCheck for leakage on both side of the drain outlet Drain hole Drain plug Evacuating the connected pipesEnglish-48 Connect a drain hose to the drain plugIf you use a pipe shorter than 4 m24JFB or Adding RefrigerantEnglish-49 If you use a pipe longer than 4 m24JFB orCylinder with siphon English-5007stIn llan atio To check for gas leaks on the outdoor unit Performing the gas leak testsEnglish-51 Outer Tightening torqueFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-52 English-53 Smart Install modeOff / Blinking / On English-54English-55 Final check and trial operationEnglish-56 Packing and unpacking guideEnglish-57 How to connect your extended power cablesAtio 021-8255 CE English-60

AR24JRFNBWKNMG, AR24JRFSBWKNMG specifications

Samsung is renowned for its innovation and quality in the electronics industry, and the AR24JRFSBWKNMG and AR24JRFNBWKNMG air conditioners exemplify this commitment. Designed for efficiency and comfort, these models are ideal for residential and commercial spaces, providing optimal climate control.

One of the standout features of both models is the inverter technology. This technology allows the air conditioners to adjust their cooling output based on the temperature of the room, ensuring energy efficiency and consistent comfort. By running the compressor at varying speeds, these units minimize energy consumption while maintaining the desired indoor environment.

The AR24JRFSBWKNMG and AR24JRFNBWKNMG also incorporate a robust air filtration system. Equipped with a multi-stage filter, these units effectively capture dust, allergens, and other airborne particles, improving indoor air quality. This is particularly beneficial for allergy sufferers or those living in urban areas with high levels of pollution.

Noise levels are another critical consideration for any air conditioning system. Both models operate quietly, thanks to their advanced design and technology. The noise reduction features ensure that the air conditioners can function without disrupting your peace, making them suitable for bedrooms, living rooms, and office spaces.

Additionally, Samsung has prioritized user convenience with smart features. The air conditioners can be controlled remotely via a smartphone app, allowing users to adjust settings from anywhere. This smart capability ensures that your space is at the perfect temperature upon arrival, maximizing comfort and ease.

Energy efficiency is further complemented by the inclusion of a high-efficiency compressor, which contributes to lower electricity bills. The models have received a high Energy Efficiency Ratio (EER) rating, making them not only eco-friendly but also cost-effective.

Moreover, both air conditioners come with a sleek and modern design, seamlessly blending into a variety of interior styles. The compact size is ideal for space-saving installations, enhancing the aesthetic appeal of any room.

In summary, the Samsung AR24JRFSBWKNMG and AR24JRFNBWKNMG air conditioners provide a combination of advanced technology, energy efficiency, and aesthetic design. With features such as inverter technology, smart controls, and exceptional air filtration, these units cater to the needs of modern consumers seeking comfort and reliability in their climate control solutions.