Samsung AR24JRFNBWKNMG, AR24JRFSBWKNMG manual Drain hose installation, English-46

Page 46

Installing and connecting the drain hose of the indoor unit

5cm

less

Keep a clearance of at least

5 cm between the end of the drain hose and the ground.

Ditch

Do not place the end of the drain hose in a hollow.

After completing the installation of the drain hose, pour water into the drain pan to check whether the hose is well drained.

1) Correct connection

2) Incorrect connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain hose

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe

Drain hose

Pipe

• Don’t tie drain hose to the assembly pipe which may lead to water leakage.

• If the diameter of the connection hose is smaller than the product's drain hose, water leakage may occur.

Drain hose installation

1.If necessary, connect the 2 meter extension drain hose to the drain hose.

2.If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.

3.Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain hose tightly with a clamp.

• If you do not use the other drain hose hole, block it with a rubber stopper.

4.When extending the Drain Hose, hold the end of Drain Hose and Extended Hose, rotate and insert the drain hose into Extended hose for 40~45 mm Make sure the two hoses are firmly connected, there is no water leakage.

Drain hose hole

5.Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose. Then, Use vinyl tape to wrap the each side of connection by 20 mm .

 

 

 

40~45 mm

20 mm

20 mm

 

 

 

or more

or more

Drain hose

Extension

 

Extension

 

 

 

drain hose

Drain hose

 

 

 

 

drain hose

Vinyl Tape

Foam Insulation

 

 

 

 

English-46

MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-05188A-00_UX.indd 46

 

 

2/17/2015 2:14:19 PM

 

 

 

 

 

 

Image 46
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Operation ranges Checking before useEnglish-10 Technical Specifications English-11English-12 AR24JRFNCWK/MGDisplay Checking the name of the partsMain parts English-13Remote controller buttons Checking the remote controllerEnglish-14 Storing the remote controller Remote controller displayLow Battery warning Inserting the batteriesBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-17 Horizontal air flow Adjusting the air flow directionVertical air flow English-18You can adjust the fan speed in Cool/Fan/Heat ARJQ mode Setting the On/Off timerSetting the On timer English-19English-20 Setting the Off timerButton Mode Additional options available in modeEnglish-21 Step cooling function English-22English-23 Using the Fast functionUsing the Comfort function Press the Options buttonEnglish-24 Using the Single User functionPress the Single user button Setting the Beep sound Using the Auto Clean functionEnglish-25 Such as thinner, kerosene and acetone etc. to clean Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerEnglish-27 Cleaning the air filterRemoving the Air filter Remove the air filter from the main bodyEnglish-28 Reassembling the Air filterTop of the Air filter into the main body.. ➀ Maintaining the air conditioner English-29English-30 TroubleshootingAir conditioner Take the cover off and takeError is indicated Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Heard when refrigerant flow movement changes. It is normalGeneral information English-32Power supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit Indoor unitOutdoor Unit Where sulfide gas existsEnglish-34 English-35 When installing more than 1 outdoor unitTop view Side view Accessories in the outdoor unit case AccessoriesAccessories in the indoor unit case English-36Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsAssembling the hanger screw English-38Removing the Cover panel Before mounting the indoor unit This QR code for detail video of indoor unit installationRemoving the screws English-39Assembling the Cover panel After mounting the indoor unit English-40Connecting the cable Connecting the assembly cableCable specification English-41Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryEnglish-42 Cut off the remaining foam insulation English-43Smooth the cut edges TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-44 English-45 Drain hose installation English-46English-47 Changing direction of the drain hoseCheck for leakage on both side of the drain outlet Connect a drain hose to the drain plug Evacuating the connected pipesEnglish-48 Drain hole Drain plugIf you use a pipe longer than 4 m24JFB or Adding RefrigerantEnglish-49 If you use a pipe shorter than 4 m24JFB orEnglish-50 Cylinder with siphonOuter Tightening torque Performing the gas leak testsEnglish-51 07stIn llan atio To check for gas leaks on the outdoor unitFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-52 Smart Install mode English-53English-54 Off / Blinking / OnFinal check and trial operation English-55Packing and unpacking guide English-56English-57 How to connect your extended power cablesAtio English-60 021-8255 CE

AR24JRFNBWKNMG, AR24JRFSBWKNMG specifications

Samsung is renowned for its innovation and quality in the electronics industry, and the AR24JRFSBWKNMG and AR24JRFNBWKNMG air conditioners exemplify this commitment. Designed for efficiency and comfort, these models are ideal for residential and commercial spaces, providing optimal climate control.

One of the standout features of both models is the inverter technology. This technology allows the air conditioners to adjust their cooling output based on the temperature of the room, ensuring energy efficiency and consistent comfort. By running the compressor at varying speeds, these units minimize energy consumption while maintaining the desired indoor environment.

The AR24JRFSBWKNMG and AR24JRFNBWKNMG also incorporate a robust air filtration system. Equipped with a multi-stage filter, these units effectively capture dust, allergens, and other airborne particles, improving indoor air quality. This is particularly beneficial for allergy sufferers or those living in urban areas with high levels of pollution.

Noise levels are another critical consideration for any air conditioning system. Both models operate quietly, thanks to their advanced design and technology. The noise reduction features ensure that the air conditioners can function without disrupting your peace, making them suitable for bedrooms, living rooms, and office spaces.

Additionally, Samsung has prioritized user convenience with smart features. The air conditioners can be controlled remotely via a smartphone app, allowing users to adjust settings from anywhere. This smart capability ensures that your space is at the perfect temperature upon arrival, maximizing comfort and ease.

Energy efficiency is further complemented by the inclusion of a high-efficiency compressor, which contributes to lower electricity bills. The models have received a high Energy Efficiency Ratio (EER) rating, making them not only eco-friendly but also cost-effective.

Moreover, both air conditioners come with a sleek and modern design, seamlessly blending into a variety of interior styles. The compact size is ideal for space-saving installations, enhancing the aesthetic appeal of any room.

In summary, the Samsung AR24JRFSBWKNMG and AR24JRFNBWKNMG air conditioners provide a combination of advanced technology, energy efficiency, and aesthetic design. With features such as inverter technology, smart controls, and exceptional air filtration, these units cater to the needs of modern consumers seeking comfort and reliability in their climate control solutions.