Samsung SMO-150TRP, SMO-150MP/UMG manual Appendix, Door Bell Occurrence, Specifications, Eng-16

Page 16

3)Loss occurrence information is stored in the ”EVENT LIST”.

4)When the corresponding camera is reconnected, the old settings are canceled and the factory default settings are reinstated.

4.Door Bell Occurrence

The Door Bell option is only available when a Door Bell Box is con- nected.

1)When a door bell is pressed, the current picture switches to the doorbell area monitoring picture, in full screen mode, along with an alarming beep.

04/01/01 12:30:30

CH 1

2)When the Door Bell is pressed, a still screen is stored in the “DOOR BELL LIST”.

3)Up to 8 still images can be stored in the “DOOR BELL LIST” and the selected List can be displayed on the screen.

NO.1 04/01/01

CH 5 12:30:30

4)Select the desired list from “6. DOOR BELL LIST ” in the SETUP MENU and press ENTER in to replay the still screen of the corresponding Door Bell.

Press ENTER again to return to the “DOOR BELL LIST”.

Appendix

Specifications

1.Model Name

-SMO-210TRN(P)

-SMO-150TRN(P)

2.Video Input

-CAMERA 8 Input : 1.0Vp-p, 75Ω (vertical), RJ-45 Type, CVBS

-VCR 1 Input (to Video Out of VCR) : 1.0Vp-p, 75Ω (vertical), S-Jack Type, CVBS

3.Video Output

-Monitor 2 Output

SPOT : 1.0 Vp-p, 75Ω (vertical), S-Jack Type, CVBS

SLAVE : 1.0 Vp-p, 75Ω (vertical), S-Jack Type, CVBS

-VCR 1 Output : 1.0 Vp-p, 75Ω (vertical), S-Jack Type, CVBS

4.Voice Input

-CAMERA 8 Input: RJ-45 Type

-VCR 1 Input (Audio Out-VCR) : S-Jack Type

5.Voice Output

-SPOT Audio

-VCR Audio

6.Alarm/Motion Function: Connected Alarm Box/Camera

-A/O (HOT, COLD): Relay Active

-A/R (Alarm Reset): Open Collector “L ” Level,

Pulse Width = 150ms or above

-Alarm Hold Time: Select 5sec, 15sec, 30sec, 1min, 3min, 5min, 10min, 20min, 30min, or AUTO.

-If AUTO is selected, the Alarm will be on during the time the Alarm trigger is received.

7.Sequence: Select between 01 sec to 30 sec.

8.Event Replay

-Alarm/Motion/Loss: Max. 16 Frames per Channel

-Door Bell: Max. 8 Frames

9.List

-Alarm/Loss/Motion: Saving Max. 50

-Door Bell: Max. 8

10.Multi Screen

-Full, 4, 8, 9, 16, Zoom, PIP

11.Horizontal Resolution

-400 TV Lines or more (Live Mode Full Screen)

12.Memory Back Up

-5 Years or more

13.Operation Temperature

-0 °C ~ 40 °C

14.Built-in Clock

-± 1 Minute/Month or less

15.CRT

-SMO-210TRN(P) : 21”FLAT CRT

-SMO-150TRN(P) : 15”FLAT CRT

16.Dimensions (W x H x D)

-SMO-210TRN(P) : 520 x 509 x 486

-SMO-150TRN(P) : 388 x 459 x 379

17.Weight

-SMO-210TRN(P) : 28kg (without packing)

32.5kg (with packing)

-SMO-150TRN(P) : 15.2kg (without packing) 18.5kg (with packing)

18. Power consumption

- Please see the regulatory label attached on the back of the monitor.

19. Video system

-SMO-210TRP/150TRP: ONLY PAL VIDEO SYSTEM

-SMO-210TRN/150TRN: ONLY NTSC VIDEO SYSTEM

Eng-16

Image 16
Contents Color Monitor Do Not Expose This Equipment To Rain or Moisture Graphic Symbol ExplanationEng-2 Contents Functions and Features OverviewOverview Names and Functions of PartsEng-5 Installation Basic Operation When you want to watch on Zoom Screen Mode When you want to watch on PIP Screen ModeWhen you want to watch the VCR output When you want to watch the Event Replay screenSetup Menu Settings View SettingCLOCK/DISPLAY SET Eng-9Camera Setup Eng-10Eng-11 ShutterSpecial Motion DetectSystem Setting AlarmAlarm Hold Time Alarm BuzzerEng-13 Alarm, Motion, Loss and Door Bell RecordingEvent List Door Bell ListLoss Occurrence Motion OccurrenceEng-15 Specifications AppendixDoor Bell Occurrence Eng-16Troubleshooting Eng-17
Related manuals
Manual 174 pages 53.3 Kb