Chapter 2: Installation
Installation Environments
This section describes the environmental requirements for safe installa- tion and use.
Install the product on a flat table or in a rack. It should be used only when level and should not be used when stood vertically or obliquely. The location in which the main system is installed and the configuration of the wiring room are very important for proper operation of the system. When the products are installed too closely together or the location is poorly ventilated, the system may not operate properly and maintenance of the system may be difficult.
Sufficiently circulate the air within the system operating room and tightly fasten the cover of the main system to prevent malfunction and reduce system downs due to environmental causes.
There are high voltage parts inside. Do not arbitrarily open the cover.
Install the product in a place that meets the following environmental con- ditions. Be sure to maintain the system under the temperatures and humidity conditions given below:
•Operating temperature : 0 °C ~ 40 °C
•Storage temperature :
•Operating humidity : 20% ~ 85% RH
•Storage humidity : 20% ~ 95 RH
•Input voltage : AC 100 ~ 240V
•Frequency: 50/60 Hz
Caution
When operating the product, the fluctuation of input voltage must be within 10% of the rated voltage and the external power outlet must be grounded, otherwise, it may cause electric shock or malfunction of the product. Do not connect
Be sure to coil
Unpacking
Remove the package cover and place the product on a flat and secure surface or in the installation location. Check whether all the following devices and accessories are included with the main system.
Color Monitor | Remote Control/ | User’s Guide |
| Batteries |
|
Power Cord | ||
| Accessory(AUX) | (VCR) |
Chapter 3: Connecting to External Devices
The product can be connected to an external device such as a monitor, VCR, Alarm Box, Door Bell Box, etc.
This chapter describes how to connect to external devices.
Caution
Make sure not to input more than 2V from the camera, video, or audio source, otherwise, it may cause a malfunction of the product.
1. Connecting to Time Lapse VCR
TIME LAPSE VCR |
|
OR NORMAL VCR VIDEO IN | VIDEO OUT |
AUDIO IN | AUDIO OUT |
TRIGGER OUT | TRIGGER |
VIDEO OUT | VIDEO IN |
AUDIO OUT | AUDIO IN |
(or Normal VCR)
1)Connect the
2)Connect the VIDEO OUT plug to the VIDEO IN terminal of the VCR.
3)Connect the VIDEO IN plug to the VIDEO OUT terminal of the VCR.
4)Connect the AUDIO OUT plug to the AUDIO IN terminal of the VCR.
5)Connect the AUDIO IN plug to the AUDIO OUT terminal of the VCR.
6)Connect the TRIGGER plug to the REC TRIGGER OUT terminal of the VCR.
7)Connect the A/O (HOT) terminal on the rear panel to the Alarm IN terminal of the VCR.
8)Connect the A/O (COLD) terminal on the rear panel to the Ground terminal of the VCR.
9)Connect the A/R terminal on the rear panel to the Alarm Reset terminal of the VCR.
10)Connect the G (ground) terminal on the rear panel to the Ground terminal of the VCR.
Caution
The name of the REC TRIGGER OUT or Alarm terminal may change depending on the type of Time Lapse VCR.
Make sure to check the names of the terminals before connecting them.
2. Connecting the Alarm Sensor
Connect the Alarm Box and Alarm Sensor in accordance with the user manual of Alarm Box.
3. Connecting the Door Bell Box
Connect the cameras and Door Bell Box in accordance with the user manual of Door Bell Box.