FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:

All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to determine the need for a permit prior to commencing the installation.

NOTE: Failure to follow these instructions could cause a malfunction of the fireplace, which could result in death, serious bodily injury, and/or property damage.

Failure to follow these instructions may also void your fire insurance and/or warranty.

GENERAL

Installation and repair should be done by a qualified service person. The appliance should be inspected before the first use and, at least, annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative the control compartments, burners and circulating air passageways of the appliance be kept clean.

Due to high temperatures, the appliance should be located out of high traffic areas and away from furniture and draperies.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burn or clothing ignition.

Young children should be carefully supervised when in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.

Clothing or other flammable materials should not be placed on or near the appliance.

WARNING

HOT GLASS WILL

CAUSE BURNS

DO NOT TOUCH GLASS

UNTIL COOLED.

NEVER ALLOW

CHILDREN TO TOUCH

GLASS.

FOR YOUR SAFETY

Installation and service must be performed by a qualified installer, service agency or gas supplier.

This installation must conform to local codes or, in the absence of local codes, to the current CAN/CGA-B149 installation code (Canada) or National Fuel Gas Code ANSI Z223.1.2 (USA)

To prevent injury, do not allow anyone who is unfamiliar with the stove to operate it.

To prevent injury, if the pilot or pilot and burners have gone out on their own, open the glass door and wait 5 minutes to air out before attempting to re- light the stove.

Always keep the area around these appliances clear of combustible material, gasoline and other flammable liquids and vapours.

These appliances should not be used as a drying rack for clothing or for hanging Christmas stockings/decorations.

Due to the paint curing on the stove, a faint odor and slight smoking will likely be noticed when the stove is first used. Open a window until the smoking stops.

Always connect this gas stove to a vent system and vent to the outside of the building envelope. Never vent to another room or inside the building. Make sure the specified vent pipe is used, properly sized and of adequate height to provide sufficient draft. Inspect the venting system annually for blockage and signs of deterioration.

WARNING: Failure to position the parts in accordance with the diagrams in this booklet, or failure to use only parts specifically approved with this appliance, may result in property damage or personal injury.

WARNING: Do not operate with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Never use solid fuels such as wood, paper, cardboard, coal, or any flammable liquids, etc., in this appliance.

Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control or gas control systems that have been under water.

Do not abuse the glass by striking it or slamming the door shut.

2

Image 2
Contents S H E R W O O D I N D U S T R I E S L T D InstallerConsumer Safety Precautions GeneralTable of Contents This Enviro DV42DX Fireplace Codes And ApprovalsVented GAS Fireplace Heater DV42DX NG/LPG Dimensions SpecificationsInstallation Options Rating Label LocationOperating Instructions Pilot Lighting InstructionsAir Diverter Control Venturi AdjustmentPilot Light To Turn GAS Fireplace OFF Maintenance And Service No substitute materials are allowedCleaning Decorative Surfaces Glass Door RemovalBurner and Fan Removal Removal of DV42DX Burner and FanWay, and snap into place Kit Parts ListConversion Kit Installation Fuel ConversionMust be not visible Removing valve ScrewInitial Installation Introduction PlacementCorner Installation Raised Fireplaces and HearthsRock or Brick Finish If the face Fireplace SurroundMantel Clearances Vent Termination RestrictionsQnty Description KIT ComponentsFireplace Horizontal Vent Kit Installation Instructions Wire Spacer in PlaceManufacturer Trade Name Nominal Sizes Other Approved Vent PartsDirect Vent Secure Vent Ameri Vent Description Temp SV4L6Venting To a chimney flue serving a separate solid-burningAppliances Vent Configurations and Restrictor Settings Possible Vent ConfigurationsHorizontal Termination Horizontal Vent TerminationAssemble Vertical TerminationRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Ducting Heat Dumping OptionsWiring Diagram For Gas Valve Electrical RequirementsGAS Line Connection To Test Valve PressuresLog Set and Ember Installation Secondary InstallationImportant installation notes Never operate the fireplace with the glass door removedFirst Stage Log Set Installation Fourth Stage Log Set Installation Troubleshooting Problem Possible Cause SolutionParts List Components Reference Description Part NumberPartsomponentsC Diagram Parts List Options Reference Options Part NumberParts Diagram Options Warranty To the DealerWarranty Warranty Installation Data Sheet

50-645, C-10078, C-11278 specifications

Enviro C-11278, 50-645, and C-10078 are innovative solutions designed to address the growing environmental challenges faced by industries today. These products are crafted with a forward-thinking approach, centered on sustainability, efficiency, and effectiveness in various applications.

One of the main features of Enviro C-11278 is its advanced formulation that combines bio-based components with traditional materials, resulting in a product that minimizes environmental impact while maintaining high performance. This formulation is designed to reduce emissions, lower toxicity, and enhance biodegradability, making it an eco-conscious choice for industries ranging from manufacturing to construction.

The Enviro 50-645 stands out for its versatility and adaptability in various operational settings. Engineered to function effectively under diverse conditions, it integrates seamlessly into different processes, requiring minimal adjustments. Its robust composition ensures durability and longevity, reducing the need for frequent replacements, and ultimately contributing to waste reduction.

C-10078 is particularly noted for its cutting-edge technology that incorporates smart monitoring capabilities. This feature allows for real-time data collection and analysis, enabling users to optimize processes and reduce resource consumption. The intelligent design not only enhances efficiency but also supports compliance with environmental regulations, making it a valuable asset for companies striving for sustainability.

In terms of characteristics, all three products exhibit high resistance to chemical degradation, ensuring consistent performance over extended periods. They are also formulated to be water-resistant, providing reliability in varied environmental conditions. The eco-friendly nature of these products does not compromise their performance; conversely, they are designed to outperform many traditional solutions in both effectiveness and safety.

Furthermore, the manufacturing processes for Enviro C-11278, 50-645, and C-10078 focus on minimizing energy consumption and reducing waste. By prioritizing renewable resources and sustainable practices, these products not only serve their intended purpose but also align with global efforts to combat climate change.

In summary, Enviro C-11278, 50-645, and C-10078 represent a significant advancement in environmentally responsible product offerings. Their unique features, innovative technologies, and commitment to sustainability position them as optimal choices for industries looking to reduce their ecological footprint while ensuring operational efficiency and safety. By integrating such products, businesses can take meaningful steps towards a greener future.