Enviro C-10078, C-11278, 50-645 Codes And Approvals, Vented GAS Fireplace Heater DV42DX NG/LPG

Page 4

Codes And Approvals

DIRECT VENT ONLY: This type is identified by the prefix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.

This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.

In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 (610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level. Refer also to local authorities or codes which have jurisdiction in your area regarding the de-rate guidelines.

In Canada: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high altitude rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).

This appliance has been tested by INTERTEK (Warnock Hersey) and found to comply with the established VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows:

VENTED GAS FIREPLACE HEATER (DV42DX; NG/LPG)

TESTED TO: ANSI Z21.88a-2003/CSA 2.33a-2003 VENTED GAS FIREPLACE HEATERS

CAN/CGA 2.17-M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES

CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY

This ENVIRO DV42DX Fireplace:

Has been certified for use with either natural or propane gases. (See rating label.)

Is not for use with solid fuels.

Is approved for bedroom or bed sitting room. (IN CANADA: must be installed with a listed wall

thermostat. IN USA: see current ANSI Z223.1 for installation instructions.)

• Must be installed in accordance with local codes. If none exist, use current installation code CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.

Must be properly connected to an approved venting system and not connected to a chimney flue serving a separate solid-fuel burning appliance.

IMPORTANT NOTICE (Regarding first fire up): When the unit is turned on for the first time, it should be turned onto high without the fan on for the first 4 hours. This will cure the paint, logs, gasket material and other products used in the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke and can irritate some people. After the unit has gone through the first burn, turn the unit off including the pilot, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer.

4

Image 4
Contents Consumer InstallerS H E R W O O D I N D U S T R I E S L T D Safety Precautions GeneralTable of Contents Vented GAS Fireplace Heater DV42DX NG/LPG Codes And ApprovalsThis Enviro DV42DX Fireplace Specifications Installation OptionsDimensions Rating Label LocationOperating Instructions Pilot Lighting InstructionsPilot Light Venturi AdjustmentAir Diverter Control To Turn GAS Fireplace OFF Maintenance And Service No substitute materials are allowedCleaning Decorative Surfaces Glass Door RemovalBurner and Fan Removal Removal of DV42DX Burner and FanKit Parts List Conversion Kit InstallationWay, and snap into place Fuel ConversionMust be not visible Removing valve ScrewInitial Installation Introduction PlacementCorner Installation Raised Fireplaces and HearthsRock or Brick Finish If the face Fireplace SurroundMantel Clearances Vent Termination RestrictionsFireplace Horizontal Vent Kit KIT ComponentsQnty Description Installation Instructions Wire Spacer in PlaceManufacturer Trade Name Nominal Sizes Other Approved Vent PartsDirect Vent Secure Vent Ameri Vent Description Temp SV4L6Appliances To a chimney flue serving a separate solid-burningVenting Vent Configurations and Restrictor Settings Possible Vent ConfigurationsHorizontal Termination Horizontal Vent TerminationAssemble Vertical TerminationRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Ducting Heat Dumping OptionsWiring Diagram For Gas Valve Electrical RequirementsGAS Line Connection To Test Valve PressuresSecondary Installation Important installation notesLog Set and Ember Installation Never operate the fireplace with the glass door removedFirst Stage Log Set Installation Fourth Stage Log Set Installation Troubleshooting Problem Possible Cause SolutionParts List Components Reference Description Part NumberPartsomponentsC Diagram Parts List Options Reference Options Part NumberParts Diagram Options Warranty To the DealerWarranty Warranty Installation Data Sheet

50-645, C-10078, C-11278 specifications

Enviro C-11278, 50-645, and C-10078 are innovative solutions designed to address the growing environmental challenges faced by industries today. These products are crafted with a forward-thinking approach, centered on sustainability, efficiency, and effectiveness in various applications.

One of the main features of Enviro C-11278 is its advanced formulation that combines bio-based components with traditional materials, resulting in a product that minimizes environmental impact while maintaining high performance. This formulation is designed to reduce emissions, lower toxicity, and enhance biodegradability, making it an eco-conscious choice for industries ranging from manufacturing to construction.

The Enviro 50-645 stands out for its versatility and adaptability in various operational settings. Engineered to function effectively under diverse conditions, it integrates seamlessly into different processes, requiring minimal adjustments. Its robust composition ensures durability and longevity, reducing the need for frequent replacements, and ultimately contributing to waste reduction.

C-10078 is particularly noted for its cutting-edge technology that incorporates smart monitoring capabilities. This feature allows for real-time data collection and analysis, enabling users to optimize processes and reduce resource consumption. The intelligent design not only enhances efficiency but also supports compliance with environmental regulations, making it a valuable asset for companies striving for sustainability.

In terms of characteristics, all three products exhibit high resistance to chemical degradation, ensuring consistent performance over extended periods. They are also formulated to be water-resistant, providing reliability in varied environmental conditions. The eco-friendly nature of these products does not compromise their performance; conversely, they are designed to outperform many traditional solutions in both effectiveness and safety.

Furthermore, the manufacturing processes for Enviro C-11278, 50-645, and C-10078 focus on minimizing energy consumption and reducing waste. By prioritizing renewable resources and sustainable practices, these products not only serve their intended purpose but also align with global efforts to combat climate change.

In summary, Enviro C-11278, 50-645, and C-10078 represent a significant advancement in environmentally responsible product offerings. Their unique features, innovative technologies, and commitment to sustainability position them as optimal choices for industries looking to reduce their ecological footprint while ensuring operational efficiency and safety. By integrating such products, businesses can take meaningful steps towards a greener future.