Chauvet LEG-6000, 6000X Shut, CoLo, Focu, dP.SE, turn, rSET, Segment Display Configurations

Page 12
{Shut} - Shutter auto-close

Operating Instructions

{Shut} - Shutter auto-close

The shutter will close momentarily during color changes. The shutter will re-open once the desired color is reached.

FUNCTION

SET TO

NOTES

Shut

Off

Normal

On

Shutter auto-close

{CoLo} - Color wheel linear/step behavior

This function set to “Off” will allow the linear or gradual progression for the selection of a color on the color wheel. It gives the user the ability to stop the wheel in between colors. The default “On” setting advances the color wheel full or complete steps.

FUNCTION

SET TO

NOTES

CoLo

Off

Linear progression

On

Step advance

{Focu} – Manual focus

The user can use this function to manually adjust the focus. This feature can be used in conjunction with operating the demo show or during maintenance and alignment.

FUNCTION

SET TO

NOTES

Focu

Off

Normal

On

Adjust focus

Segment Display Configurations

{dP.SE} - Display Auto-off

The led display can be set to automatically turn off during normal operations.

FUNCTION

SET TO

NOTES

dP.SE

Off

Display Auto-Off, press any

key to turn on display

 

On

Always on

{turn} Reverse the display

FUNCTION

SET TO

NOTES

turn

Off

Normal display

On

Invert display

Service Functions

{rSEt} - Fixture Reset (all motors)

This function will re-initialize the fixture by returning all motors to its startup positions or otherwise known as (home position).

FUNCTION

SET TO

NOTES

rSET

Off

Normal

On

Reset all motors

LEG-6000 User Manual

12

Revision: 2007-03-06/09:06

Image 12
Contents LEG-6000 Legend 6000X 575WRevision 2007-03-06/09 TABLE OF CONTENT What is included AC PowerSafety Instructions Before You BeginControl Features FeaturesINTRODUCTION DMX Channel SummaryProduct Overview 1 2 5SETUP Lamp InstallationLamp Power Power Cable ConfigurationMounting OrientationRigging d a aOPERATING INSTRUCTIONS Control BoardControl Board Functions All turnApplying changes to Functions Quick Instructions Operating ModeMenu Functions DMX-512addressingUser Configurations Setting the starting addressr.Pan r.tiltSegment Display Configurations Service FunctionsrSEt - Fixture Reset all motors ShutdF.SE - Fixture Reset excludes Pan & Tilt Fi.ti - Fixture TimerdF.SE dEMoAPPENDIX DMX PrimerFixture Linking DMX Channel Values 16 Bit MovementDip Switches settings explained 8 Bit MovementAll Off 1-OnMaintenance Returns ProcedureColor Calibration ClaimsGeneral Troubleshooting Technical Specifications Technical SupportWEIGHT & DIMENSIONS POWER