Power
| Your product is equipped with an internal |
|
| ||
Warning! | Verify that the power select switch on your unit matches the line voltage applied. All | ||||
| fixtures must be connected to circuits with a suitable Earth Ground. | ||||
| • To determine the power requirements for |
|
| Remove the right base | |
|
|
| cover panel as | ||
| 2 |
| |||
| a particular fixture, see the label affixed to |
| |||
|
| illustrated here to gain | |||
| the back plate of the fixture or refer to the |
| access to the switch | ||
| fixture’s specifications chart. |
|
| shown below. | |
| • A fixture’s listed current rating is its |
|
|
|
|
|
|
| 3 |
| |
| average current draw under normal |
|
|
| |
| conditions. |
|
|
|
•All fixtures must be powered directly off a
switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.
•Before applying power to a fixture, check that the
source voltage matches the fixture’s |
|
|
requirement. | Input Voltage Switch 3,4,5 | |
• All fixtures must be connected to circuits | ||
with a suitable Earth Ground. |
|
|
1.Make sure the fixture is not connected to power, if so disconnect.
2.Remove the right base access cover panel as illustrated on the right.
3.Locate the power selection switches and dial.
4.Rotate the voltage dial to the setting that most closely matches the local AC voltage. If your voltage falls halfway between two settings, select the higher voltage on the dial.
5.Move the frequency switch to the setting that matches the local AC frequency; 50 or 60 Hz.
6.Replace access cover.
Power Cable Configuration
CABLE | PIN | INTERNATIONAL |
BROWN | Live | L |
BLUE | Neutral | N |
YELLOW/GREEN | Earth | EG (Ground) |
|
|
|
7 | Revision: |