SETUP
Lamp
You will need to install a lamp prior to the initial operation of the fixture. A HMI575 high intensity discharge lamp is included.
Warning! | When replacing the lamp, please wait 15 minutes after powering down to allow the |
| unit to cool down! Always disconnect from main power prior to lamp replacement. |
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp with alcohol and wipe it with a lint free cloth before installation.
Lamp Installation |
| S1 | |
1. Unscrew thumbscrews (S1) to |
| ||
|
| ||
detach the top cover. |
|
| |
|
| 1 | |
2. Unscrew screws (S2) to remove | 1 |
| |
|
| ||
lamp cover and expose lamp | S2 | 2 | |
compartment. | |||
|
| ||
|
| 3 |
3. | Move lamp reflector back as indicated by the arrow. |
|
|
|
|
| |
4. | If installing a new lamp, loosen both screws on the |
|
|
|
|
| |
| double ended lamp to allow for the lamp to slide into the |
|
|
|
|
| |
| lamp socket slots. Lower lamp evenly. |
|
|
|
|
| |
5. | If replacing a lamp, loosen both lamp screws |
|
|
|
|
|
|
| (S3) to relieve tension from lamp socket slots |
| S3 | 5 |
| ||
| so you can slide the lamp freely, upwards and |
|
| ||||
| out of lamp socket. Raise lamp evenly to |
|
|
|
|
|
|
| remove. |
|
|
|
|
|
|
6. | Before you tighten the lamp end screws, |
|
|
|
|
|
|
| rotate the bulb until the nipple on the envelope |
|
|
|
|
|
|
| (N) of the bulb is facing upwards as illustrated. |
|
|
|
|
|
|
7. | If you are replacing the lamp, you may want to |
|
|
|
|
|
|
|
|
|
| 6 | |||
| log the fixture hours in order to track the lamps |
|
|
|
| ||
|
|
|
|
| |||
| use. Navigate to the {LPti} on the menu display to obtain this | ||||||
| information. (Page 9, Control Board Functions) |
|
|
| 5 |
N
6 | Revision: |