Chauvet LEG-6000, 6000X user manual Appendix, DMX Primer, Fixture Linking

Page 14
APPENDIX

APPENDIX

DMX Primer

There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX-512 will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in advance. Channels should never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is set incorrectly. You can however, control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation. In other words, the fixtures will be slaved together and all respond exactly the same.

DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)

Figure 1 - DMX connector configuration

 

 

COMMON

 

1

DMX +

INPUT

3

 

 

2

DMX -

 

 

 

1

Resistance 120

 

3

ohm 1/4w between

 

pin 2

(DMX -) and

 

2

 

pin 3

(DMX +) of

 

 

the last fixture.

1

OUTPUT

 

 

3

 

 

2

Termination reduces signal errors and to

avoid signal transmission problems and interference, it is always advisable to connect a DMX signal terminator.

 

Fixture Linking

Note!

If you use a controller with a 5 pin DMX output connector, you will need to use a 5

 

pin to 3 pin adapter. CHAUVET Model No: DMX5M.

 

The chart below details a proper cable conversion:

 

3 PIN TO 5 PIN CONVERSION CHART

Conductor

3 Pin Female (output)

 

 

Ground/Shield

Pin 1

 

 

Data ( - )signal

Pin 2

 

 

Data ( + ) signal

Pin 3

 

 

Do not use

 

 

 

Do not use

 

 

 

5 Pin Male (Input)

Pin 1

Pin 2

Pin 3

Do not use

Do not use

LEG-6000 User Manual

14

Revision: 2007-03-06/09:06

Image 14
Contents Revision 2007-03-06/09 LEG-6000Legend 6000X 575W TABLE OF CONTENT Safety Instructions What is includedAC Power Before You BeginINTRODUCTION Control FeaturesFeatures DMX Channel SummaryProduct Overview 1 2 5Lamp SETUPLamp Installation Power Power Cable ConfigurationRigging MountingOrientation d a aControl Board Functions All OPERATING INSTRUCTIONSControl Board turnMenu Functions Applying changes to Functions Quick InstructionsOperating Mode DMX-512addressingr.Pan User ConfigurationsSetting the starting address r.tiltrSEt - Fixture Reset all motors Segment Display ConfigurationsService Functions ShutdF.SE dF.SE - Fixture Reset excludes Pan & TiltFi.ti - Fixture Timer dEMoFixture Linking APPENDIXDMX Primer DMX Channel Values 16 Bit MovementAll Off Dip Switches settings explained8 Bit Movement 1-OnColor Calibration MaintenanceReturns Procedure ClaimsGeneral Troubleshooting WEIGHT & DIMENSIONS Technical SpecificationsTechnical Support POWER