EdgeStar AP410W manual Wall installation permanent mounting

Page 10

Wall installation (permanent mounting)

Key for the above diagram:

1.Exhaust port

2.Vent connector

3.Exhaust hose

4.Round adapter

1.Drill a 5 1/8” diameter (approx.) hole through the wall. For safety and to avoid cutting into structural support beams or electrical wires, please have a qualified technician drill this hole.

2.Insert the round adapter into the hole (from inside the room) and mark the screw hole positions on the wall

3.Remove the round adapter from the wall and drill four screw holes in the positions marked.

4.Replace the round adapter into the wall and screw it into place.

5.Move the portable air conditioner into place near the wall and insert the exhaust hose into the round adapter. Twist the exhaust hose into the adapter in a clockwise direction.

6.When not in use, remove the exhaust hose from the round adapter and place the round adapter cap over the hole.

10

Image 10
Contents Page Table of contents Thank you Energy saving tips Safety precautions SpecificationsPage Front view PartsRear view Accessories Installation Installing the exhaust hoseWindow installation Wall installation permanent mounting Page LED indicators Control panelSetting up the remote control Remote ControlButtons Remote control functions Page Regulating airflow direction Drain parts Manual drainageDraining with the drain tray Cleaning the condenser coils MaintenanceCleaning the exterior Prefilter and charcoal filterCleaning the prefilter Installing the charcoal filterLong term storage Troubleshooting Problem Possible Causes SolutionsPage Plug Testing Instructions Lcdi plug wring instructionLimited warranty What is Covered