Heatiator GC150 owner manual VI. Operating Instructions

Page 19

GC150 SERIES DIRECT VENT GAS APPLIANCE

VI. OPERATING INSTRUCTIONS

STANDING PILOT

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's

phone. Follow the supplier's instructions.

If you cannot reach your gas supplier, call the fire depart- ment.

C.Use only your hand to push in or turn knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Forced or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

STOP! Read the safety information above on this label!

1. Turn off all wall switches to the appliance.

6

 

2Lower bottom access panel. Turn wall switch to

the “OFF” position or set thermostat to lowest setting.

3Turn gas line to CLOSED. Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step.

2

4 Turn gas line to OPEN.

5 Turn pilot knob clockwise to “OFF”. (Knob may have to be depressed to pass “PILOT” position.)

6Locate pilot assembly inside unit.

7Locate red ignitor button.

8Turn pilot knob to “PILOT” and push in.

9.Continue to hold in pilot knob and push the red ignitor button 12-15 times until small blue pilot

flame appears.

3

10. Continue to hold in pilot knob for approximately

7

one minute. Pilot should remain lit. If pilot goes

4

out, wait 5 minutes and repeat Steps 4-9.

 

11To light the main burner, release and turn knob counterclockwise to “ON”. If the fireplace is con- nected to a wall switch, turn it to “ON”. Do not light by hand.

12.If the appliance will not operate, follow the

instructions “To Turn Off Gas To Appliance” and

 

 

 

call your service technician or gas supplier.

5

8

11

TO TURN OFF GAS TO APPLIANCE

1.Turn off the wall switch or set the thermo- stat to the lowest setting.

2.Remove control access panel.

3.Turn gas line to CLOSED position. Do not force.

4.Replace control access panel.

4-99

19

21322M

Image 19
Contents Models GC150, GC150L, GC150E, GC150LE Table of Contents II. Description of the Fireplace System Listings and Code ApprovalsCatalog Number Description III. Fireplace System ComponentsVent Sections Wall ShieldRoof Flashing Firestop Spacer Vertical Termination Cap EL45Fireplace Locations and Clearances IV. PRE-INSTALLATION PreparationFinishing Materials Framing the FireplaceTermination Nailing Flanges Positioning the FireboxGC150 Series Direct Vent GAS Appliance Cm minimum Horizontal Termination Cap Locations Dimension DescriptionsVertical Termination GC150 Series Direct Vent GAS Appliance Gas Line Gas line installationVenting System Termination Height Double CheckingLower Panel Removal Electronic Ignition Wiring DiagramStanding Pilot Ignition Standing Pilot Ignition Wiring DiagramLocation of Panels Hood PlacementAttaching Hood FinishingArranging the Logs Positioning the Logs Positioning the LogsReplacing the Panels Glass ReplacementPlacing the Rock Wool Glass Replacement Screen Replacement Lower Panel ReplacementVI. Operating Instructions Standing Pilot Ignition Determining the Ignition TypeLower Panel Removal Standing Pilot Operation Side View of Panel Lower Front Face ReplacementVII. Maintenance Instructions Electronic Ignition GC150E VIII. Trouble ShootingStanding Pilot Electronic Ignition GC150E IX. Replacement PartsAppliance Installer

GC150 specifications

The Heatiator GC150 is an innovative heating solution designed to provide efficient warmth in various residential and commercial settings. With an emphasis on technology and user experience, the GC150 combines modern features with powerful performance. Its sleek design fits harmoniously into different interior styles, making it a beautiful addition to any space.

One of the standout features of the Heatiator GC150 is its advanced heating technology. The unit utilizes a highly efficient heating element that quickly warms up a room while minimizing energy consumption. This energy-efficient operation not only helps reduce utility bills but also promotes a more sustainable approach to heating. The GC150 is equipped with a programmable thermostat, allowing users to set their desired temperature and optimize energy usage based on personal schedules.

The Heatiator GC150 also boasts a rapid heating capability, ensuring that it delivers consistent warmth even in large areas. This is achieved through its convection heating design, which circulates warm air evenly throughout the room. The result is a comfortable, balanced environment without cold spots or drafts.

Safety features are another significant aspect of the Heatiator GC150. The unit includes an overheating protection mechanism that automatically shuts off the device if it reaches an unsafe temperature. Additionally, the GC150 is designed with a sturdy, cool-touch exterior, preventing burns or accidental injuries, making it suitable for homes with children or pets.

Another important characteristic of the GC150 is its quiet operation. Unlike traditional heating units that can be noisy, the Heatiator GC150 runs silently, allowing for an undisturbed environment. This is particularly beneficial for bedrooms, offices, or other spaces where concentration and relaxation are essential.

Ease of use is prioritized with the Heatiator GC150, featuring user-friendly controls and an informative digital display. Users can effortlessly navigate through various settings, select heat levels, and adjust timers for convenient operation.

In summary, the Heatiator GC150 is a versatile and efficient heating solution that offers a blend of innovation, safety, and user convenience. Its advanced features, such as programmable thermostats, rapid heating capabilities, and quiet operation, make it a worthwhile investment for any setting, ensuring comfort throughout the colder months without compromising energy efficiency.