Heatiator GC150 owner manual Framing the Fireplace, Finishing Materials

Page 7

GC150 SERIES DIRECT VENT GAS APPLIANCE

E. FRAMING THE FIREPLACE

Note: If an optional fan (FK4) or hand held remote control (RC4 or RC5) are to be used, wiring must be done prior to finishing to avoid reconstruction.

Note: The remote wall switch must be wired prior to applying the finishing material in order to avoid reconstruction.

The GC150 Series Gas Appliance will fit a framed opening of 40" w X 1612" d X 3018" h.

Figure 2 - Framing the Fireplace

Figures 2 and 2a show a typical framing of this fire- place assuming combustible materials are used. All required clearances to combustibles around the fire- place must be adhered to. A 1/2" air clearance must be maintained at the back and sides of the firebox assembly. A minimum of 38” is required to the bot- tom of a 7” mantle. Anything greater than 7” must be 42” above the base of the unit. Any framing on top of the fireplace must be above the top standoffs. Vent sections for a horizontal run require a 3" minimum air space on top and a 1" minimum air space on the sides and bottom. Vertical rise sections require a 1" minimum air space completely around the vent sec- tions.

Flue outside diameter: 8"

Minimum firestop framing: 10" X10"

Face of header to the center of the firestop spacer (FS6) framing: 87/8"

Note: The outside walls of the home around the fire place should be insulated and finished as one would any other outside wall, while maintain- ing the 1/2"air clearance around the firebox.

Figure 2a

Framing the Fireplace

F. FINISHING MATERIALS

Only non-combustible materials may be used to cover the black surfaces of the fireplace front.

Combustible Finishing Material. Material made of or surfaced with wood, compressed paper, plant fibers, plastics, or any material capable of igniting and burning, whether flame proofed or not, plastered or unplastered.

Non-combustible Finishing Material. Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, con- crete, slate, glass or plasters, or combination thereof.

High Temperature Sealant Material. Sealants that will withstand high temperatures (300° F+); General Electric RTV103 (Black), or equivalent. Rutland, Inc. Fireplace Mortar #63, or equivalent.

After completing the framing and applying the finish- ing material (dry wall) over the framing, a non-com- bustible sealant, one-half inch wide maximum, must be used to close off any gaps at the top and sides between the fireplace and facing to prevent cold air leaks. See Figure 3.

Figure 3

Finishing Materials

WARNING!

AIR SLOTS ON THIS APPLIANCE CAN- NOT, IN ANY WAY, BE COVERED AS IT MAY CREATE A FIRE HAZARD.

12-98

7

21322K

Image 7
Contents Models GC150, GC150L, GC150E, GC150LE Table of Contents II. Description of the Fireplace System Listings and Code ApprovalsCatalog Number Description III. Fireplace System ComponentsVent Sections Wall ShieldRoof Flashing Firestop Spacer Vertical Termination Cap EL45Fireplace Locations and Clearances IV. PRE-INSTALLATION PreparationFinishing Materials Framing the FireplaceTermination Nailing Flanges Positioning the FireboxGC150 Series Direct Vent GAS Appliance Cm minimum Horizontal Termination Cap Locations Dimension DescriptionsVertical Termination GC150 Series Direct Vent GAS Appliance Gas Line Gas line installationVenting System Termination Height Double CheckingLower Panel Removal Electronic Ignition Wiring DiagramStanding Pilot Ignition Standing Pilot Ignition Wiring DiagramLocation of Panels Hood PlacementAttaching Hood FinishingArranging the Logs Positioning the Logs Positioning the LogsReplacing the Panels Glass ReplacementPlacing the Rock Wool Glass Replacement Screen Replacement Lower Panel ReplacementVI. Operating Instructions Standing Pilot Ignition Determining the Ignition TypeLower Panel Removal Standing Pilot Operation Side View of Panel Lower Front Face ReplacementVII. Maintenance Instructions Electronic Ignition GC150E VIII. Trouble ShootingStanding Pilot Electronic Ignition GC150E IX. Replacement PartsAppliance Installer

GC150 specifications

The Heatiator GC150 is an innovative heating solution designed to provide efficient warmth in various residential and commercial settings. With an emphasis on technology and user experience, the GC150 combines modern features with powerful performance. Its sleek design fits harmoniously into different interior styles, making it a beautiful addition to any space.

One of the standout features of the Heatiator GC150 is its advanced heating technology. The unit utilizes a highly efficient heating element that quickly warms up a room while minimizing energy consumption. This energy-efficient operation not only helps reduce utility bills but also promotes a more sustainable approach to heating. The GC150 is equipped with a programmable thermostat, allowing users to set their desired temperature and optimize energy usage based on personal schedules.

The Heatiator GC150 also boasts a rapid heating capability, ensuring that it delivers consistent warmth even in large areas. This is achieved through its convection heating design, which circulates warm air evenly throughout the room. The result is a comfortable, balanced environment without cold spots or drafts.

Safety features are another significant aspect of the Heatiator GC150. The unit includes an overheating protection mechanism that automatically shuts off the device if it reaches an unsafe temperature. Additionally, the GC150 is designed with a sturdy, cool-touch exterior, preventing burns or accidental injuries, making it suitable for homes with children or pets.

Another important characteristic of the GC150 is its quiet operation. Unlike traditional heating units that can be noisy, the Heatiator GC150 runs silently, allowing for an undisturbed environment. This is particularly beneficial for bedrooms, offices, or other spaces where concentration and relaxation are essential.

Ease of use is prioritized with the Heatiator GC150, featuring user-friendly controls and an informative digital display. Users can effortlessly navigate through various settings, select heat levels, and adjust timers for convenient operation.

In summary, the Heatiator GC150 is a versatile and efficient heating solution that offers a blend of innovation, safety, and user convenience. Its advanced features, such as programmable thermostats, rapid heating capabilities, and quiet operation, make it a worthwhile investment for any setting, ensuring comfort throughout the colder months without compromising energy efficiency.