Heatiator GC150 owner manual VII. Maintenance Instructions

Page 24

GC150 SERIES DIRECT VENT GAS APPLIANCE

VII. MAINTENANCE INSTRUCTIONS

Cleaning the burner and control compartment

Keep the burner and control compartment clean by brushing and vacuuming at least once a year. Always turn off the gas valve and the ON/OFF switch before cleaning.

Checking flame patterns

Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. The flame color should be blue with yellow tips. The ignitor (electronic) or thermopile (stand- ing pilot) tips should be covered with flame. See Figures 41 through 44.

Venting system inspection

The appliance and venting system should be inspected before use, and at least annually, by a qualified field service person, to ensure that the flow of combustion and ventilation air is not obstructed.

Cleaning the glass

Note: When cleaning the glass, NEVER use abrasive materials. NEVER clean glass when hot. Keep pets and children a safe distance away.

It is recommended to wear gloves while handling or removing glass. DO NOT REMOVE GLASS WHEN HOT.

Clean glass after initial one hour burn. This is to remove any film that develops from oils and log burn in time. After initial cleaning, clean as needed.

To remove the glass for cleaning, follow Step 11 on page 16. Handle glass panel with care to avoid striking or scratching it on hard objects.

To clean the glass, use a non-abrasive automotive rubbing com- pound and glass cleaner. Simply apply an adequate amount to the glass and wipe off per manufacturers instructions. Contact your local stove shop or fireplace accessaries store for further rec- ommendations.

Never operate this appliance without the glass properly secured in place or if the glass is broken.

In the event of glass breakage, follow glass removal instructions to remove the top retaining strip. Remove lower retaining strip in the same manner. This will allow the removal of all glass frag- ments and sheet metal edge protection strips. Vacuum all remaining glass pieces with a shop vac. (DO NOT VACUUM IF PIECES ARE HOT.) Replace glass only with Heatilator part num- ber 15573 ordered direct or through your local distributor. Never use substitute material. Only fully tempered soda lime safety glass or optional ceramic glass may be used on this appliance.

Log cleaning

Logs can be easily lifted out of position. Carbon build-up can be removed with a vacuum cleaner.

To prevent the possibility of soot, we have provided your fireplace with an adjustable air shutter. Your air shutter is provided in an open position to ensure clean operation under normal situations. In the even that soot is accumulating in your appliance, the air shutter should be opened farther as shown in Figure 44. This can be done with a screwdriver or a 1/4” wrench. Also, ensure logs are positioned correctly to minimize flame contact with the logs.

Figure 41

Electronic Ignition

Figure 42

Electronic Ignition

Figure 43

Standing Pilot

Figure 44

Both Ignitions

12-98

24

21322K

Image 24
Contents Models GC150, GC150L, GC150E, GC150LE Table of Contents Listings and Code Approvals II. Description of the Fireplace SystemIII. Fireplace System Components Catalog Number DescriptionWall Shield Roof FlashingFirestop Spacer Vertical Termination Cap EL45 Vent SectionsIV. PRE-INSTALLATION Preparation Fireplace Locations and ClearancesFraming the Fireplace Finishing MaterialsPositioning the Firebox Termination Nailing FlangesGC150 Series Direct Vent GAS Appliance Horizontal Termination Cap Locations Dimension Descriptions Cm minimumVertical Termination GC150 Series Direct Vent GAS Appliance Gas line installation Venting System Termination HeightDouble Checking Gas LineElectronic Ignition Wiring Diagram Lower Panel RemovalStanding Pilot Ignition Wiring Diagram Standing Pilot IgnitionHood Placement Attaching HoodFinishing Location of PanelsPositioning the Logs Arranging the Logs Positioning the LogsGlass Replacement Placing the Rock Wool Glass Replacement Screen ReplacementLower Panel Replacement Replacing the PanelsVI. Operating Instructions Determining the Ignition Type Standing Pilot IgnitionLower Panel Removal Standing Pilot Operation Lower Front Face Replacement Side View of PanelVII. Maintenance Instructions VIII. Trouble Shooting Electronic Ignition GC150EStanding Pilot IX. Replacement Parts Electronic Ignition GC150EAppliance Installer

GC150 specifications

The Heatiator GC150 is an innovative heating solution designed to provide efficient warmth in various residential and commercial settings. With an emphasis on technology and user experience, the GC150 combines modern features with powerful performance. Its sleek design fits harmoniously into different interior styles, making it a beautiful addition to any space.

One of the standout features of the Heatiator GC150 is its advanced heating technology. The unit utilizes a highly efficient heating element that quickly warms up a room while minimizing energy consumption. This energy-efficient operation not only helps reduce utility bills but also promotes a more sustainable approach to heating. The GC150 is equipped with a programmable thermostat, allowing users to set their desired temperature and optimize energy usage based on personal schedules.

The Heatiator GC150 also boasts a rapid heating capability, ensuring that it delivers consistent warmth even in large areas. This is achieved through its convection heating design, which circulates warm air evenly throughout the room. The result is a comfortable, balanced environment without cold spots or drafts.

Safety features are another significant aspect of the Heatiator GC150. The unit includes an overheating protection mechanism that automatically shuts off the device if it reaches an unsafe temperature. Additionally, the GC150 is designed with a sturdy, cool-touch exterior, preventing burns or accidental injuries, making it suitable for homes with children or pets.

Another important characteristic of the GC150 is its quiet operation. Unlike traditional heating units that can be noisy, the Heatiator GC150 runs silently, allowing for an undisturbed environment. This is particularly beneficial for bedrooms, offices, or other spaces where concentration and relaxation are essential.

Ease of use is prioritized with the Heatiator GC150, featuring user-friendly controls and an informative digital display. Users can effortlessly navigate through various settings, select heat levels, and adjust timers for convenient operation.

In summary, the Heatiator GC150 is a versatile and efficient heating solution that offers a blend of innovation, safety, and user convenience. Its advanced features, such as programmable thermostats, rapid heating capabilities, and quiet operation, make it a worthwhile investment for any setting, ensuring comfort throughout the colder months without compromising energy efficiency.