Heath Zenith Motion Sensing Coach Lights manual Complete Installation, Testing, Maximum Range

Page 5

COMPLETE THE

INSTALLATION

Stuff the wires into the junction box. Make sure the wires from the fixture go through the wire path, and no wires get pinched.

Slide the fixture onto the

Junction

mounting screws and

Box

tighten nuts.

 

Caulk fixture mounting surface with silicone weather sealant. You may want to wait until you have completed the tests and adjustments on page 6.

Install one 100 W max. light bulb.

TESTING

Turn on the circuit breaker and light switch.

Note: Sensor has a 1 1/2 minute warm up pe- riod before it will detect motion.When first turned on wait 1 1/2 minutes.

Note: Meets the ENERGY STAR® guidelines when DualBrite® function is off.

Switch the on-time to TEST position and DualBrite® switch to the OFF position.

TEST 1 5 10 MIN

OFF 3 6 DUSK TO

ON-TIME

HOUR DAWN

Avoid aiming the control at:

Pools of water or objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearbylarge,light-coloredobjectsreflect- ing daylight may trigger the shut-off feature. Do not point other lights at the sensor.

150°

6 ft.

(1.8 m)

30ft.

(9.1m)

Maximum Range

Maximum

 

Coverage Angle

598-1207-01

Image 5
Contents Some codes require installation by a qualified electrician FeaturesOperation RequirementsDualBrite Dimmer Control InstallationMode Switching Summary Rotated WiringAs Shipped Optional Wiring Testing Complete InstallationTurn on the circuit breaker and light switch Maximum RangeLeast Sensitive SpecificationsNo Service Parts Available for this Product Troubleshooting GuideRequisitos FuncionamientoCaracterísticas ADVERTENCIADesconecte la ener- gía en el disyuntor InstalacionLuz de Adorno DualBrite Girada CableadoComo se enviaron Conexion Alterna Prueba Complete LA InstalacionAlcance Máximo Angulo de Cobertura Máxima Prenda el cortacircuitos y el interruptor de luzLo menos sensible Lo más sensible EspecificacionesNo hay piezas de servicio disponibles para este producto Guia DE Investigacion DE AveriasCaractéristiques FonctionnementExigences Minuterie DualBriteMD Résumé du mode de commutationCâblage Méthode de mise à la terre recommandéeTel qu’expédié Après rotationCâblage Facultatif Essais Complétez LinstallationLe moins sensible Le plus sensible Fiche TechniqueAucune pièce de rechange n’est disponible pour ce produit Guide DE Dépannage598-1207-01 598-1207-01 598-1207-01