Heath Zenith Motion Sensing Coach Lights manual Troubleshooting Guide

Page 7

TROUBLESHOOTING GUIDE

If you experience a problem with your coach light, follow this guide before returning it to

the retailer.

SYMPTOM

POSSIBLE CAUSE

 

 

 

Light will not

1.

Light switch is turned off.

come on.

2. Bulb is loose or burned out.

 

3.

Fuse is blown or circuit breaker

 

 

is turned off.

 

4.

Daylight turn-off is in effect

 

 

(recheck after dark).

 

5.

Incorrect circuit wiring, if this

 

 

is a new installation.

 

6.

Re-aim the sensor to cover

 

 

desired area.

 

 

Light comes on

1. Light control may be installed

in daylight.

 

in a relatively dark location.

 

2.

Light control is in Test. (Set

 

 

control switch to an ON-TIME

 

 

position.)

 

 

 

Light comes on

1.

Light control may be sensing

for no apparent

 

small animals or automobile

reason.

 

traffic (re-aim sensor).

 

2.

Sensitivity is set too high.

 

 

(Reduce sensitivity.)

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

Light stays on

1. The sensor is pointed toward

continuously.

 

a heat source like an air vent,

 

 

dryer vent, or brightly-painted

 

 

heat-reflective surface.(Re-aim

 

 

sensor.)

 

2.

Light control is in Manual Mode.

 

 

(Switch to Auto.)

 

3.

Light control is in DualBrite®

 

 

mode.

 

4.

Sensitivity is set too high. (Re-

 

 

duce sensitivity.)

 

 

 

Light flashes

1.

Sensor is in the Test mode.

on and off.

 

(While inTEST mode, light only

 

 

stays on for 5 seconds.)

 

2.

Heat being reflected from other

 

 

objects may be affecting the

 

 

sensor. (Re-aim sensor.)

 

 

 

Light does not

1.

Nearby large, light-colored

stay on in Man-

 

objects reflecting light may

ual mode.

 

trigger the shut-off feature. Do

 

 

not point other lights at the

 

 

sensor.

 

 

 

No Service Parts Available for this Product

See your Canadian Tire retailer for warranty information.

598-1207-01

Image 7
Contents Requirements FeaturesSome codes require installation by a qualified electrician OperationMode Switching Summary InstallationDualBrite Dimmer Control As Shipped WiringRotated Optional Wiring Maximum Range Complete InstallationTesting Turn on the circuit breaker and light switchLeast Sensitive SpecificationsNo Service Parts Available for this Product Troubleshooting GuideCaracterísticas FuncionamientoRequisitos Luz de Adorno DualBrite InstalacionADVERTENCIADesconecte la ener- gía en el disyuntor Como se enviaron CableadoGirada Conexion Alterna Prenda el cortacircuitos y el interruptor de luz Complete LA InstalacionPrueba Alcance Máximo Angulo de Cobertura MáximaLo menos sensible Lo más sensible EspecificacionesNo hay piezas de servicio disponibles para este producto Guia DE Investigacion DE AveriasExigences FonctionnementCaractéristiques Minuterie DualBriteMD Résumé du mode de commutationAprès rotation Méthode de mise à la terre recommandéeCâblage Tel qu’expédiéCâblage Facultatif Essais Complétez LinstallationLe moins sensible Le plus sensible Fiche TechniqueAucune pièce de rechange n’est disponible pour ce produit Guide DE Dépannage598-1207-01 598-1207-01 598-1207-01